Alerts

Alerts

Signal Name Description Condition Impact
Steering Torque Overlay (STO) assist halted due to Primary excessive current failure.
Primary Internal: excessive current detected by current sensor (80 or more Amps) for 50ms
Steering Assist reduced
Steering Torque Overlay (STO) assist halted due to Secondary main current sensor offset startup failure.
Secondary Internal: main current sensor offset failure detected on startup for 250ms
Steering Assist reduced
Steering Torque Overlay (STO) assist halted due to Primary current estimate failure.
Primary Internal: current estimate is inaccurate (by 20 or more Amps) for 50ms
Steering Assist reduced
Steering Torque Overlay (STO) assist halted due to Secondary current estimate failure.
Secondary Internal: current estimate is inaccurate (by 20 or more Amps) for 50ms
Steering Assist reduced
Steering Torque Overlay (STO) assist halted due to Secondary excessive current failure.
Secondary Internal: excessive current detected by current sensor (80 or more Amps) for 50ms
Steering Assist reduced
Steering Torque Overlay (STO) assist halted due to sensor power supply voltage startup failure.
Internal: torque sensor power supply voltage on low side < 3.0 Volts, or high side not within 4.71 Volts and 5.26 Volts on startup for 250ms
Steering Assist reduced
Steering Torque Overlay (STO) assist halted due to sensor power supply voltage failure.
Internal: torque sensor power supply voltage not within 4.71 Volts and 5.26 Volts for 2ms
Steering Assist reduced
Steering Torque Overlay (STO) assist halted due to Secondary pre-driver fault pin startup failure.
Secondary Internal: pre-driver board voltage failure detected at high or low side for 2ms
Steering Assist reduced
Steering Torque Overlay (STO) assist halted due to Secondary pre-driver fault pin startup failure.
Secondary Internal: pre-driver fault pin failure detected on startup for 250ms
Steering Assist reduced
Steering Torque Overlay (STO) assist halted due to Secondary pre-driver fault pin failure.
Secondary Internal: pre-driver fault pin failure detected for 5 or 50ms
Steering Assist reduced
Steering Torque Overlay (STO) assist halted due to Secondary pre-driver VDS comparator startup failure.
Secondary Internal: pre-driver Drain to Source Voltage (VDS) comparator failure detected on startup for 250ms
Steering Assist reduced
Steering Torque Overlay (STO) assist halted due to Secondary pre-driver VGS monitor startup failure.
Secondary Internal: pre-driver Gate Source Voltage (VGS) function failure detected on startup for 250ms
Steering Assist reduced
Steering Torque Overlay (STO) assist halted due to Secondary pre-driver current sensor short startup failure.
Secondary Internal: pre-driver current sensor short detected on startup for 250ms
Steering Assist reduced
A software trip has been detected due to High Voltage (HV) readings dropping below the expected undervoltage limit.
HV voltage drops below the expected undervoltage threshold.
STITCH will halt operation, low voltage will not be supported.
A fast firmware trip has been detected due to High Voltage (HV) readings exceeding the expected bus top half voltage limit.
Single HV top half bus voltage exceeds the expected threshold.
STITCH will halt operation, low voltage will not be supported.
A software trip has been detected due to the stage 1 Low Voltage (LV) side board temperature sensor exceeding the expected temperature limit.
Stage 1 LV temperature sensor reads above the expected threshold.
STITCH will halt operation, low voltage will not be supported.
A software trip has been detected due to the stage 2 low voltage side board temperature sensor exceeding the expected temperature limit.
Stage 2 LV temperature sensor reads above the expected threshold.
STITCH will halt operation, low voltage will not be supported.
A software trip has been detected due to the stage 1 high voltage side board temperature sensor exceeding the expected temperature limit.
Stage 1 HV temperature sensor reads above the expected threshold.
STITCH will halt operation, low voltage will not be supported.
A software trip has been detected due to the stage 2 high voltage side board temperature sensor exceeding the expected temperature limit.
Stage 2 HV temperature sensor reads above the expected threshold.
STITCH will halt operation, low voltage will not be supported.
The Sigma Delta Filter Module (SDFM) peripheral is not powered, potentially due to not enough DC voltage being provided to the SDFM.
One of the SDFM modules indicates either a clock failure or an irrational reading.
STITCH will halt operation, low voltage will not be supported.