Signal Name Description Condition Impact
A controller trip error has been detected due to Low Voltage (LV) current measurement and reference exceeding the expected difference threshold during steady state operation.
LV voltage current measurement and reference difference is above the expected threshold for the given time interval.
STITCH will halt operation due to LV current controller failure.
One of the temperature sensors is reporting an out of range reading.
One of the temperature sensors is reporting an out of range reading.
STITCH will throw warning without halting operation.
The 1V5 reference voltage reading is outside of the expected minimum and maximum thresholds.
The 1V5 reference voltage is outside of the expected minimum and maximum range for the given time interval.
STITCH will throw warning.
The ambient temperature sensor reading exceeds the expected temperature threshold.
The ambient temperature sensor reading exceeds the expected temperature threshold.
STITCH will throw warning.
The device junction temperature sensor reading exceeds the expected temperature threshold.
The device junction temperature sensor reading exceeds the expected temperature threshold.
STITCH will throw warning.
STITCH has been locked out due to an environmental or hardware condition preventing normal operation.
STITCH encounters a hardware or environmental condition preventing normal operation.
STITCH will be persistently locked out.
The STITCH Low Voltage (LV) temperature sensor has detected the internal over temperature threshold exceeds 25.0 degC.
The STITCH LV temperature sensor has detected the internal over temperature threshold exceeds 25.0 degC.
This alert has no functional impact on the vehicle.
Steering Torque Overlay (STO) assist halted due to Primary motor inverter driver startup short circuit failure 1.
Primary Internal: motor inverter driver short circuit detected on startup for 250ms
Steering Assist reduced
Steering Torque Overlay (STO) assist halted due to low Power Supply voltage.
Critical Power Supply voltage <= 7.3 Volts for 1 second
Steering Assist reduced
Steering Torque Overlay (STO) assist halted due to high Power Supply voltage.
Internal: Voltage between Fail Safe Relay 1 and 2 >= 18.5 Volts for 1 second
Steering Assist reduced
Steering Torque Overlay (STO) assist halted due to 3.3 Volt Power Supply failure.
Internal: 3.3V Power Supply voltage >= 3.5 Volts or <= 3.09 Volts for 20ms
Steering Assist reduced
Steering Torque Overlay (STO) assist halted due to Primary FS relay short circuit startup failure 1.
Primary Internal: Fail Safe (FS) Relay(s) detected a short on startup for 250ms
Steering Assist reduced
Steering Torque Overlay (STO) assist halted due to Primary FS relay short circuit startup failure 2.
Primary Internal: Fail Safe (FS) Relay(s) detected a short on startup for 250ms
Steering Assist reduced
Steering Torque Overlay (STO) assist halted due to Primary FS relay short circuit startup failure 3.
Primary Internal: Fail Safe (FS) Relay(s) detected a short on startup for 250ms
Steering Assist reduced
Steering Torque Overlay (STO) assist halted due to Primary FS relay 2 open circuit startup failure.
Primary Internal: Fail Safe (FS) Relay 2 detected an open circuit on startup for 250ms
Steering Assist reduced
Steering Torque Overlay (STO) assist halted due to Primary FS relay open circuit.
Primary Internal: Fail Safe (FS) Relay(s) detected an open circuit for 45ms
Steering Assist reduced
Steering Torque Overlay (STO) assist halted due to Secondary Secondary FS relay short circuit startup failure 1.
Secondary Internal: Fail Safe (FS) Relay(s) detected a short on startup for 250ms
Steering Assist reduced
Steering Torque Overlay (STO) assist halted due to Secondary FS relay short circuit startup failure 2.
Secondary Internal: Fail Safe (FS) Relay(s) detected a short on startup for 250ms
Steering Assist reduced
Steering Torque Overlay (STO) assist halted due to Secondary FS relay short circuit startup failure 3.
Secondary Internal: Fail Safe (FS) Relay(s) detected a short on startup for 250ms
Steering Assist reduced
Steering Torque Overlay (STO) assist halted due to Secondary FS relay 2 open circuit startup failure.
Secondary Internal: Fail Safe (FS) Relay 2 detected an open circuit on startup for 250ms
Steering Assist reduced