Alerts
Loading...
Signal Name | Description | Condition | Impact |
---|---|---|---|
A controller trip error has been detected due to Low Voltage (LV) current measurement and reference exceeding the expected difference threshold during steady state operation.
|
LV voltage current measurement and reference difference is above the expected threshold for the given time interval.
|
STITCH will halt operation due to LV current controller failure.
|
|
One of the temperature sensors is reporting an out of range reading.
|
One of the temperature sensors is reporting an out of range reading.
|
STITCH will throw warning without halting operation.
|
|
The 1V5 reference voltage reading is outside of the expected minimum and maximum thresholds.
|
The 1V5 reference voltage is outside of the expected minimum and maximum range for the given time interval.
|
STITCH will throw warning.
|
|
The ambient temperature sensor reading exceeds the expected temperature threshold.
|
The ambient temperature sensor reading exceeds the expected temperature threshold.
|
STITCH will throw warning.
|
|
The device junction temperature sensor reading exceeds the expected temperature threshold.
|
The device junction temperature sensor reading exceeds the expected temperature threshold.
|
STITCH will throw warning.
|
|
STITCH has been locked out due to an environmental or hardware condition preventing normal operation.
|
STITCH encounters a hardware or environmental condition preventing normal operation.
|
STITCH will be persistently locked out.
|
|
The STITCH Low Voltage (LV) temperature sensor has detected the internal over temperature threshold exceeds 25.0 degC.
|
The STITCH LV temperature sensor has detected the internal over temperature threshold exceeds 25.0 degC.
|
This alert has no functional impact on the vehicle.
|
|
Steering Torque Overlay (STO) assist halted due to Primary motor inverter driver startup short circuit failure 1.
|
Primary Internal: motor inverter driver short circuit detected on startup for 250ms
|
Steering Assist reduced
|
|
Steering Torque Overlay (STO) assist halted due to low Power Supply voltage.
|
Critical Power Supply voltage <= 7.3 Volts for 1 second
|
Steering Assist reduced
|
|
Steering Torque Overlay (STO) assist halted due to high Power Supply voltage.
|
Internal: Voltage between Fail Safe Relay 1 and 2 >= 18.5 Volts for 1 second
|
Steering Assist reduced
|
|
Steering Torque Overlay (STO) assist halted due to 3.3 Volt Power Supply failure.
|
Internal: 3.3V Power Supply voltage >= 3.5 Volts or <= 3.09 Volts for 20ms
|
Steering Assist reduced
|
|
Steering Torque Overlay (STO) assist halted due to Primary FS relay short circuit startup failure 1.
|
Primary Internal: Fail Safe (FS) Relay(s) detected a short on startup for 250ms
|
Steering Assist reduced
|
|
Steering Torque Overlay (STO) assist halted due to Primary FS relay short circuit startup failure 2.
|
Primary Internal: Fail Safe (FS) Relay(s) detected a short on startup for 250ms
|
Steering Assist reduced
|
|
Steering Torque Overlay (STO) assist halted due to Primary FS relay short circuit startup failure 3.
|
Primary Internal: Fail Safe (FS) Relay(s) detected a short on startup for 250ms
|
Steering Assist reduced
|
|
Steering Torque Overlay (STO) assist halted due to Primary FS relay 2 open circuit startup failure.
|
Primary Internal: Fail Safe (FS) Relay 2 detected an open circuit on startup for 250ms
|
Steering Assist reduced
|
|
Steering Torque Overlay (STO) assist halted due to Primary FS relay open circuit.
|
Primary Internal: Fail Safe (FS) Relay(s) detected an open circuit for 45ms
|
Steering Assist reduced
|
|
Steering Torque Overlay (STO) assist halted due to Secondary Secondary FS relay short circuit startup failure 1.
|
Secondary Internal: Fail Safe (FS) Relay(s) detected a short on startup for 250ms
|
Steering Assist reduced
|
|
Steering Torque Overlay (STO) assist halted due to Secondary FS relay short circuit startup failure 2.
|
Secondary Internal: Fail Safe (FS) Relay(s) detected a short on startup for 250ms
|
Steering Assist reduced
|
|
Steering Torque Overlay (STO) assist halted due to Secondary FS relay short circuit startup failure 3.
|
Secondary Internal: Fail Safe (FS) Relay(s) detected a short on startup for 250ms
|
Steering Assist reduced
|
|
Steering Torque Overlay (STO) assist halted due to Secondary FS relay 2 open circuit startup failure.
|
Secondary Internal: Fail Safe (FS) Relay 2 detected an open circuit on startup for 250ms
|
Steering Assist reduced
|