| Signal Name | Description | Condition | Impact |
|---|---|---|---|
|
This alert is reported when there is a GDU communication failure
|
EPAS ECU GDU device monitor detected failure (wrong parity bit on serial communication). After consecutives retries and error is still present.
|
EPAS full loss of assist.
|
|
|
This alert is reported by the StreamingDataStorageManager_R12 (SDSM) component when the CRC is not equal to saved CRC value at any memory block, but another is correct
|
CRC is not equal to saved CRC value at any memory block, but another is correct.
|
EPAS fast restart was not possible.
|
|
|
This alert is reported when the wake-up (WKP) or overrun (OVRUN) bits is set in the PMSWSTAT2 register
|
The wake-up (WKP) or overrun (OVRUN) bits is set in the PMSWSTAT2 register. PMSWSTAT2.ESR0WKP is set after reset.
|
EPAS reset. If reset more than 3 times then EPAS full loss of assist.
|
|
|
This alert is reported by MCUSafetyStartupChecks_TC3x (MCUSSC) component when wrong ECU_ID in FLASH
|
EPAS End Of Line ECU ID is incorrect.
|
EPAS full loss of assist.
|
|
|
This alert is reported by MCUSafetyStartupChecks_TC3x (MCUSSC) component when the current MCU ID is not supported
|
EPAS End Of Line MCU ID is not supported.
|
EPAS full loss of assist.
|
|
|
This alert is reported by the ExceptionHandler_TC3x (EXCH) component when no-reset exception occurred before the previous similar exception was reported and guarded reset was requested
|
EPAS application component ExceptionHandler detected exception ( QM partition) which causes a guarded reset.
|
EPAS still can provide assist. MCU reset on the exception side.
|
|
|
This alert is reported when there is a CRC failure in the periodic register CRC checking. MCU internal error OR SW systematic failure
|
EPAS MCU periodic register checking failure (CRC doesn't match the expected).
|
EPAS reset. If reset more than 6 then EPAS fallback to bootloader.
|
|
|
This alert is reported by the ExceptionHandler_TC3x (EXCH) component when no-reset exception occured before the previous similar exception was reported
|
EPAS application component ExceptionHandler detected additional exceptions at stop/restart of partition.
|
EPAS still can provide assist. MCU reset on the exception side.
|
|
|
This alert is reported by the ExceptionHandler_TC3x (EXCH) component when exception with reaction other than reset
|
EPAS application component ExceptionHandler detected exception (QM partition) at stop/restart of partition.
|
EPAS still can provide assist. MCU reset on the exception side.
|
|
|
This alert is reported by the TemperatureDiagnostics_Actuator_R12 (TDA) component when there is a phase current shunt temperature higher than limit or not available
|
EPAS application actuator temperature diagnostics detected overtemperature (phase current shunt).
|
EPAS full loss of assist.
|
|
|
This alert is reported by MCUSafetyStartupChecks_TC3x (MCUSSC) component when the Secondary Monitor and Standby SMU Built in Self Test failure, MCU failure
|
EPAS secondary monitor and standby SMU BIST timeout
|
EPAS full loss of assist
|
|
|
This alert is reported by MCUSafetyStartupChecks_TC3x (MCUSSC) component when the memory Built-In-SelfTest failed, MCU failure
|
EPAS memory BIST timeout.
|
EPAS reset. If reset more than 6 then EPAS fallback to bootloader.
|
|
|
This alert is reported by MCUSafetyStartupChecks_TC3x (MCUSSC) component when the memory Built-In-SelfTest failed, errors in the critical memory units. MCU failure
|
EPAS memory BIST found any errors in critical memory units (CPU0, CPU1, DMA).
|
EPAS reset. If reset more than 6 then EPAS fallback to bootloader.
|
|
|
This alert is reported when the Start-up register check failed: MCU internal error OR SW systematic failure
|
EPAS microcontroller's different registers does not contain the right values before starting the safety functions (CRC doesn't match for the second test fail).
|
EPAS reset. If reset more than 6 then EPAS fallback to bootloader.
|
|
|
This alert is reported by ActuatorManager_R12 (AM) component when there is a GDU failure or current sensing failure
|
GDU failure or current sensing failure. When the GDU_FLAG_LO_CURRENT_MEASUREMENT_AMPLIFIER_DISCONNECTED bit is set in GDUStatus:GduErrorCode.
|
EPAS full loss of assist.
|
|
|
This alert is reported by the ExceptionHandler_TC3x (EXHA) component when there is a system Bus or Peripheral Error exception other than a floating point exception
|
EPAS application component ExceptionHandler detected exception (system bus or peripheral error)
|
EPAS reset
|
|
|
This alert is reported by the ExceptionHandler_TC3x (EXHA) component when there is a internal Protection exception
|
EPAS application component ExceptionHandler detected exception (internal protection).
|
EPAS reset
|
|
|
This alert is reported by the ExceptionHandler_TC3x (EXHA) component when there is a SPB bus violation
|
EPAS application component ExceptionHandler detected exception (SPB bus violation).
|
EPAS reset
|
|
|
This alert is reported by the ExceptionHandler_TC3x (EXHA) component when there is a bus level MPU violation
|
EPAS application component ExceptionHandler detected exception (bus level MPU violation).
|
EPAS reset
|
|
|
This alert is reported by the ActuatorManager_R12 (AM) component when there is a GDU or GDU-SBC connection problem
|
This alert is no longer used and replaced by EPAST_a085_amGduSwitchOffTestByMcu
|
This alert is no longer used and replaced by EPAST_a085_amGduSwitchOffTestByMcu
|