| Signal Name | Description | Condition | Impact |
|---|---|---|---|
|
The Power Conversion System (PCS) detects the DCAC ENABLE digital line is deasserted when DCAC is still commanded to operate
|
The PCS detects the DCAC ENABLE digital line is deasserted when DCAC is still commanded to operate
|
DCAC converters will be forced shutdown due to the ENABLE line deassertion
|
|
|
The DC link side DCDC converter (DCDCB) lifetime energy record not ready for use
|
The lifetime energy record for DCDCB is not in an expected state
|
Lifetime energy conversion data for DCDCB cannot be stored
|
|
|
The pack side DCDC converter (DCDCA) lifetime energy record not ready for use
|
The lifetime energy record for DCDCA is not in an expected state
|
Lifetime energy conversion data for DCDCA cannot be stored
|
|
|
Non-Volatile Memory (NVM) record transfer channel stalled
|
The NVM sub-system becomes unresponsive to a read/write request
|
Some non-volatile data may not be stored and/or retrieved
|
|
|
DCAC converter A (DCACA) resonant tank calibration data is out of specification
|
A tank capacitance or inductance measurement for DCACA is not withinthe design margin
|
DCAC operation allowed with default resonant tank parameters at reduced surge current limit
|
|
|
DCAC converter A (DCACA) resonant tank calibration data is out of specification
|
A tank capacitance or inductance measurement for DCACA is not within the design margin
|
DCAC operation allowed with default resonant tank parameters at reduced surge current limit
|
|
|
DCAC converter B (DCACB) is not operational
|
DCACB has exhausted all of its retries due to various conditions affecting functionality.
|
AC Charging may be limited or unavailable.
|
|
|
The pack side DCDC converter (DCDCA) resonant tank calibration data is out of specification
|
A tank capacitance or inductance measurement for DCDCA is not within the design margin
|
DCDC operation allowed with default resonant tank parameters, but risk of damaging the converter due to hard switching
|
|
|
The Power Conversion System (PCS) detects an unknown grid configuration from the external charging equipment
|
The PCS detects unknown grid configuration
|
AC charging functionality may be unavailable
|
|
|
DCAC converter B (DCACB) resonant tank has not been fully calibrated
|
A tank capacitance or inductance measurement for DCACB is not recorded in Non-Volatile Memory (NVM)
|
DCAC operation allowed with default resonant tank parameters at reduced surge current limit
|
|
|
DCAC converter A (DCACA) is not operational
|
DCACA has exhausted all of its retries due to various conditions affecting functionality.
|
AC Charging may be limited or unavailable.
|
|
|
The Power Conversion System (PCS) detects the DCDC ENABLE digital line is deasserted when DCDC is commanded to operate.
|
The PCS detects the DCDC ENABLE digital line is deasserted when DCDC is commanded to operate
|
DCDC converter will be forced shutdown due to this ENABLE line deassertion
|
|
|
The DC link side DCDC converter (DCDCB) resonant tank has not been fully calibrated
|
A tank capacitance or inductance measurement for DCDCB is not recorded in Non-Volatile Memory (NVM)
|
DCDC operation allowed with default resonant tank parameters, but risk of damaging the converter due to hard switching
|
|
|
The pack side DCDC converter (DCDCA) resonant tank has not been fully calibrated
|
A tank capacitance or inductance measurement for DCDCA is not recorded in Non-Volatile Memory (NVM)
|
DCDC operation allowed with default resonant tank parameters, but risk of damaging the converter due to hard switching
|
|
|
The DCAC high voltage (HV) measurement goes below the allowed voltage threshold
|
The DCAC HV voltage goes below the allowed voltage threshold
|
DCAC functionality may be limited or paused
|
|
|
The DCAC high voltage (HV) measurement goes above the allowed voltage threshold
|
The DCAC HV voltage goes above the allowed voltage threshold
|
DCAC functionality may be limited or paused
|
|
|
The sensor measuring the bottom half of the high voltage (HV) battery voltage detects a value below the allowed voltage threshold
|
The sensor measuring the bottom half of the HV battery voltage goes below the allowed voltage threshold
|
DCDC functionality may be limited or paused
|
|
|
The sensor measuring the top half of the high voltage (HV) battery voltage detects a value below the allowed voltage threshold
|
The sensor measuring the top half of the HV battery voltage goes below the allowed voltage threshold
|
DCDC functionality may be limited or paused
|
|
|
The high voltage (HV) battery goes below the allowed voltage threshold
|
The HV battery voltage goes below the allowed voltage threshold
|
DCDC functionality may be limited or paused
|
|
|
The sensor measuring the bottom half of the high voltage (HV) bus voltage detects a value below the allowed voltage threshold
|
The sensor measuring the bottom half of the HV bus voltage goes below the allowed voltage threshold
|
DCDC functionality may be limited or paused
|