Signal Name Description Condition Impact
A controller trip error has been detected due to Low Voltage (LV) current measurement and reference exceeding the expected difference threshold during steady state operation.
LV voltage current measurement and reference difference is above the expected threshold for the given time interval.
STITCH will halt operation due to LV current controller failure.
One of the temperature sensors is reporting an out of range reading.
One of the temperature sensors is reporting an out of range reading.
STITCH will throw warning without halting operation.
The 1V5 reference voltage reading is outside of the expected minimum and maximum thresholds.
The 1V5 reference voltage is outside of the expected minimum and maximum range for the given time interval.
STITCH will throw warning.
The ambient temperature sensor reading exceeds the expected temperature threshold.
The ambient temperature sensor reading exceeds the expected temperature threshold.
STITCH will throw warning.
The device junction temperature sensor reading exceeds the expected temperature threshold.
The device junction temperature sensor reading exceeds the expected temperature threshold.
STITCH will throw warning.
STITCH has been locked out due to an environmental or hardware condition preventing normal operation.
STITCH encounters a hardware or environmental condition preventing normal operation.
STITCH will be persistently locked out.
The STITCH Low Voltage (LV) temperature sensor has detected the internal over temperature threshold exceeds 25.0 degC.
The STITCH LV temperature sensor has detected the internal over temperature threshold exceeds 25.0 degC.
This alert has no functional impact on the vehicle.
Low Voltage (LV) bus voltage precharge timed out. LV rail cannot be brought up.
LV bus voltage precharge times out.
Precharge can enable at too high of a load or short on LV.
A stage 2 instantaneous hardware trip has been detected due to a stage B tank current condition.-.
The absolute tank current has exceeded the expected threshold.
The condition can lead to potential hardware damage if persistently observed.
A stage 1 instantaneous hardware trip has been detected due to a Stage A tank current condition.
The absolute tank current has exceeded the expected threshold.
The condition can lead to potential hardware damage if persistently observed.
An instantaneous hardware Low Voltage (LV) trip has been detected due to an overvoltage condition.
LV output voltage exceeds the expected overvoltage threshold.
STITCH will halt operation, low voltage will not be supported.
Steering Torque Overlay (STO) assist halted due to Power Supply SPI communication error.
Power Supply Integrated Circuit (IC) SPI communication error detected
Steering Assist reduced
An instantaneous hardware Low Voltage (LV) trip has been detected due to an overvoltage condition.
LV output voltage exceeds the expected overvoltage threshold.
STITCH will halt operation, low voltage will not be supported.
A software trip has been detected due to the stage 1 Low Voltage (LV) side board temperature sensor exceeding the expected temperature limit.
Stage 1 LV temperature sensor reads above the expected threshold.
STITCH will halt operation, low voltage will not be supported.
A fast firmware trip has been detected due to High Voltage (HV) readings exceeding the expected bus top half voltage limit.
Single HV top half bus voltage exceeds the expected threshold.
STITCH will halt operation, low voltage will not be supported.
A software trip has been detected due to High Voltage (HV) readings dropping below the expected undervoltage limit.
HV voltage drops below the expected undervoltage threshold.
STITCH will halt operation, low voltage will not be supported.
A software trip has been detected due to High Voltage (HV) bus top half voltage readings exceeding the expected limit during operation.
Single HV top half bus voltage exceeds the expected threshold.
STITCH will halt operation, high voltage will not be supported.
A software trip has been detected due to High Voltage (HV) bus bottom half voltage readings exceeding the expected limit during operation.
Single HV bottom half bus voltage exceeds the expected threshold.
STITCH will halt operation, high voltage will not be supported.
STITCH command Controller Area Network (CAN) messages are not received .
STITCH command CAN messages are Missing In Action (MIA).
STITCH will halt operation, low voltage will not be supported.
An operation on the Electrically Erasable Programmable Read-Only Memory (EEPROM) has failed. This alert provides record ID, error type, and number of errors since the last task loop.
An operation on the EEPROM failed.
The payload signals for this alert will indicate the nature of the error.