Alerts
Loading...
| Signal Name | Description | Condition | Impact | Important |
|---|---|---|---|---|
|
The seat track motor is not calibrated, which may cause position recall to be unavailable.
|
The seat track motor is detected as uncalibrated (calibrated state of the seat track motor is 0).
|
Position recall may be unavailable, meaning the preset user preferences for seat positions may also be unavailable.
|
No
|
|
|
The seat tilt motor has unexpectedly stalled.
|
Current draw exceeds stall limit.
|
Motor will recalibrate if the stall is in an expected region, do nothing otherwise.
|
No
|
|
|
The motor isn't providing encoder feedback
|
Current draw is nonzero and not stalling but encoder values don't increase
|
Memory recall will be unavailable
|
No
|
|
|
The motor has traveled beyond the expected range
|
seat position goes outside the acceptable range
|
Seat may be in an unstable position or a mechanism may have failed
|
No
|
|
|
The seat motor has traveled beyond the expected range.
|
Seat position goes outside the acceptable range.
|
Seat may be in an unstable position or a mechanism may not be functioning as expected.
|
No
|
|
|
The motor isn't providing encoder feedback
|
Current draw is nonzero and not stalling but encoder values don't increase
|
Memory recall will be unavailable
|
No
|
|
|
The motor has traveled beyond the expected range
|
seat position goes outside the acceptable range
|
Seat may be in an unstable position or a mechanism may have failed
|
No
|
|
|
The front seat heater temperature sensor has an electrical fault. This sensor is used for fault management of the airbag system
|
The sensor is disconnected or short-circuited to ground
|
Occupancy sensing will be impacted
|
No
|
|
|
The lift motor is uncalibrated
|
Motor calibrated is 0
|
Position recall unavailable
|
No
|
|
|
The tilt motor is uncalibrated
|
Motor calibrated is 0
|
Position recall unavailable
|
No
|
|
|
The valveblock isn't inflating or deflating when commanded
|
commands sent over lin solicit no action from the lumbar
|
lumbar isn't functional
|
No
|
|
|
The bladder B has exceeded pressure limits
|
Bladder pressure exceeds 1300hPa (absolute)
|
Damage to bladder or valve block
|
No
|
|
|
The front seat heater is not drawing current, which may lead to the seat heater not performing as designed.
|
The eFuse on the front controller is not tripped and the current drawn by the front seat heater is 0 amps.
|
The front seat heater may not perform as designed.
|
No
|
|
|
The seat heater has had unusually high current draw
|
Seat heater current has reached above a permitted threshold
|
Seat heater will stop running. Potential damage to harness and seat.
|
No
|
|
|
The motor isn't responding
|
Motor current is 0
|
seat motor can't move
|
No
|
|
|
The high side driver (HSD) for the front seat heater has detected a short-circuit, which may lead to the seat heater not performing as designed.
|
The high side driver (HSD) for the front seat heater detects a short-circuit.
|
The front seat heater may not perform as designed.
|
No
|
|
|
The seat track motor has unexpectedly stalled.
|
Current draw exceeds stall limit.
|
Motor will recalibrate if the stall is in an expected region, do nothing otherwise.
|
No
|
|
|
The bladder A has exceeded pressure limits
|
Bladder pressure exceeds 1300hPa (absolute)
|
Damage to bladder or valve block
|
No
|
|
|
The motor isn't responding
|
Motor current is 0
|
seat motor can't move
|
No
|
|
|
The motor isn't responding
|
Motor current is 0
|
seat motor can't move
|
No
|