Alerts
Loading...
| Signal Name | Description | Condition | Impact |
|---|---|---|---|
|
OCS Sensor reading is lower than expected
|
OCS Sensor reading tosDeltaEmpty is less than -150
|
Occupancy sensing will be impacted
|
|
|
OCS Seatback is likely disconnected
|
OCS Sensor reading tosDeltaCM is less than 590
|
Occupancy sensing will be impacted
|
|
|
The Temp Humidity occupancy sensor communication failed
|
The Temp Humidity occupancy sensor communication failed
|
Occupancy sensing will be impacted
|
|
|
The TOS communication failed
|
The TOS communication failed
|
Occupancy sensing will be impacted
|
|
|
The Cushion occupancy sensor reading does not match other occupancy sensors
|
Cushion occupancy sensor reading does not match other occupancy sensors
|
Occupancy sensing will be impacted
|
|
|
OCS both seatback and cushion likely disconnected
|
OCS Sensor reading tosDeltaCM is less than 140
|
Occupancy sensing will be impacted
|
|
|
The Cushion occupancy sensor calibration is present, but invalid
|
The Cushion occupancy sensor calibration is invalid
|
Occupancy sensing will be impacted
|
|
|
The Temp Humidity occupancy sensor calibration is missing
|
The Temp Humidity occupancy sensor is not yet calibrated or lost calibration
|
Occupancy sensing will be impacted
|
|
|
The Spare occupancy sensor calibration is present, but invalid
|
The Spare occupancy sensor calibration is invalid
|
Occupancy sensing will be impacted
|
|
|
The Temp Humidity occupancy sensor reads invalid value
|
Temp Humidity occupancy sensor reading is valid
|
Occupancy sensing will be impacted
|
|
|
The Spare occupancy sensor reads as shorted to ground
|
Spare occupancy sensor reading is less than x
|
Occupancy sensing will be impacted
|
|
|
The Spare occupancy sensor calibration is missing
|
The Spare occupancy sensor is not yet calibrated or lost calibration
|
Occupancy sensing will be impacted
|
|
|
The Temp Humidity occupancy sensor calibration is present, but invalid
|
The Temp Humidity occupancy sensor calibration is invalid
|
Occupancy sensing will be impacted
|
|
|
OCS empty seat calibration is mismatched with calibration programmed at board manufacturing
|
OCS empty seat calibration is below 590 of board manufacturing calibration
|
Occupancy sensing will be impacted
|
|
|
The Cushion occupancy sensor reads a low value
|
Cushion occupancy sensor reading is less than 23000
|
Occupancy sensing will be impacted
|
|
|
The Cushion occupancy sensor reads a high value
|
Cushion occupancy sensor reading is greater than 28000
|
Occupancy sensing will be impacted
|
|
|
The Cushion occupancy sensor reads as shorted to ground
|
Cushion occupancy sensor reading is less than x
|
Occupancy sensing will be impacted
|
|
|
The seat backrest position has reached the hard stop upper limit
|
The seat backrest position moves forward above the hard stop upper limit
|
The seat backrest position will not move forward
|
|
|
The front seat buckle sensor is faulted
|
Buckle sensor is out of spec
|
Cannot determine buckle of the seat
|
|
|
The seat backrest hard stop is disabled
|
The seat backrest hard stop is disabled
|
The seat backrest will be allowed to move forward and possibly interfere with the sunvisor
|