Signal Name Description Condition Impact
BCFDM_w040_MirrorMotor
setcondition
These are the repercussions of the alert being set
BCFDM_w039_MirrorMovement
Mirror failed to change movement states.
These are the repercussions of the alert being set
Reset the door board upon fixing the board causing the error.
Cannot initalize the switchpack
Switchpack and all window functionality disabled for that door
BCFDM_w037_ExteriorSwitch
Switch is active for 30s continuously or is disconnected
Release cannot be used to trigger door motion until fault is cleared
Need to save PFD actuator-specific calibration values into NVRAM via Toolbox
Door brake data is using default values
The door brake hold force may be wrong
BCFDM_w035_AmbientLighting
The desired state of the ambient lighting could not be set, the current state is not the expected one or the brightness adjustment did fail.
These are the repercussions of the alert being set
BCFDM_w034_WindowSwitchLED
The desired state of the window switch backlighting could not be set, the current state is not the expected one or the brightness adjustment did fail
These are the repercussions of the alert being set
BCFDM_w033_PuddleLamp
The desired state of the puddle lamp could not be set, the current state is not the expected one or the light did time out
These are the repercussions of the alert being set
BCFDM_w032_WindowCommError
Lin frame error.
These are the repercussions of the alert being set
BCFDM_w031_WindowRegulator
Error from LIN.
The windows could be malfunctioning.
Check the alert log for the specific failure code.
The latch reports an error code over LIN
The latch may fail to operate properly
Not Available
NVRAM detected as uninitialized.
These are the repercussions of the alert being set
Not Available
Unsuccessful communication with NVRAM.
These are the repercussions of the alert being set
Not Available
NVRAM detected as corrupted.
These are the repercussions of the alert being set
Not Available
Flash CRC is corrupted.
These are the repercussions of the alert being set
Check alertLog for more information. If resultingState is CLOSED_BRAKE, the latch's OPEN switch may be disconnected. If previousState is OPENED_BRAKE, the latch's switches and release motor may be all disconnected.
PFD transitions from LATCH_OPENING to CLOSED_BRAKE or OPENED_BRAKE
PFD cannot open automatically
BCFDM_w065_ratchetingDetected
If front door is releasing and braking continously
Worse user experience as the door
BCFDM_w036_InteriorSwitch
Switch is active for 30s continuously or is disconnected
Release cannot be used to trigger door motion until fault is cleared
Can sometimes be remedied by pulling/replacing fuse 233 under the MCU
Latch is not communicating over LIN
The latch may not work if it is of the cinching type
The linkage may have become detached at the ball joint. This alert is only present in factory mode.
A possible issue with the PFD acutator linkage was detected
The door shuts off all powered operation until closed and latched