Signal Name Description Condition Impact
Not Available
Unsuccessful communication with NVRAM.
These are the repercussions of the alert being set
Not Available
NVRAM detected as corrupted.
These are the repercussions of the alert being set
Not Available
Flash CRC is corrupted.
These are the repercussions of the alert being set
BCFDM_w036_InteriorSwitch
Switch is active for 30s continuously or is disconnected
Release cannot be used to trigger door motion until fault is cleared
Check alertLog for more information. If resultingState is CLOSED_BRAKE, the latch's OPEN switch may be disconnected. If previousState is OPENED_BRAKE, the latch's switches and release motor may be all disconnected.
PFD transitions from LATCH_OPENING to CLOSED_BRAKE or OPENED_BRAKE
PFD cannot open automatically
latch feedback switches are most likely harnessed incorrectly.
OPEN switch is active and AJAR switch is not active
Door latch status is incorrectly reported and PFD operation becomes erratic
The linkage may have become detached at the ball joint. This alert is only present in factory mode.
A possible issue with the PFD acutator linkage was detected
The door shuts off all powered operation until closed and latched
The door motor brake is not calibrated and using default values.
Door motor brake has no calibration data and is using default values.
The door motor brake might not function as expected. Use Service action 'Write Actuator Brake Calibration' to add it.
The log data contains failure count and up to five init failure codes.
A task init function returns with an error.
If an init routine fails, software may not opperate correctly.
Not Available
setcondition
These are the repercussions of the alert being set
Not Available
setcondition
These are the repercussions of the alert being set
Not Available
setcondition
These are the repercussions of the alert being set
Not Available
Reasons to keep the controller awake have been the same for greater than one hour
The bus could not sleep causing significant range loss for the battery pack
Not Available
A signal is received 10% out of timing 3 times in a row.
These are the repercussions of the alert being set
After a record upgrade is successful, resetting the ECU should clear the alert.
Record not found, CRC mismatch, Version mismatch, Version upgrade.
Indicate the state of non-volatile data in the ECU.
Bridge faults are most likely due to configuration error.
An fault was reported by the bridge driver while initializing or controlling the bridge driver or a bridge channel.
Some or all bridge outputs may not opperate due to a bridge fault.
This alert is used to create the template for the raw alert log. Double check before this alert is used for something else.
Set condition
These are the repercussions of the alert being set
Not Available
Reset can be caused by: Clock Error, Flash Error, Software Reset, Checkstop Reset, Debug Reset
Potential issue with hardware or software caused the reset.
This message contains separate signals for Overvoltage and Undervoltage for each rail.
ECU 5V rail detected < 4.5V or > 5.5V, or 3.3V rail < 3.0V or > 3.6V for 100ms.
These are the repercussions of the alert being set
Not Available
setcondition
These are the repercussions of the alert being set