Alerts

Alerts

Signal Name Description Condition Impact
BCFPM_w039_MirrorMovement
Mirror failed to change movement states.
These are the repercussions of the alert being set
Reset the door board upon fixing the board causing the error.
Cannot initalize the switchpack
Switchpack and all window functionality disabled for that door
BCFPM_w037_ExteriorSwitch
Switch is active for 30s continuously or is disconnected
Release cannot be used to trigger door motion until fault is cleared
BCFPM_w036_InteriorSwitch
Switch is active for 30s continuously or is disconnected
Release cannot be used to trigger door motion until fault is cleared
BCFPM_w035_AmbientLighting
The desired state of the ambient lighting could not be set, the current state is not the expected one or the brightness adjustment did fail.
These are the repercussions of the alert being set
BCFPM_w034_WindowSwitchLED
The desired state of the window switch backlighting could not be set, the current state is not the expected one or the brightness adjustment did fail
These are the repercussions of the alert being set
BCFPM_w033_PuddleLamp
The desired state of the puddle lamp could not be set, the current state is not the expected one or the light did time out
These are the repercussions of the alert being set
Not Available
Unsuccessful communication with NVRAM.
These are the repercussions of the alert being set
BCFPM_w031_WindowRegulator
Error from LIN.
The windows could be malfunctioning.
BCFPM_w032_WindowCommError
Lin frame error.
These are the repercussions of the alert being set
BCFPM_w030_LockedDoorOpened
Door state open and locked.
These are the repercussions of the alert being set
The door ice breaker extended but the door latch is not opened.
Door ice breaker started retracting while the door latch is not opened.
Door might not open due to the latch release actuator not working or an external factor blocking the door.
Not Available
Flash CRC is corrupted.
These are the repercussions of the alert being set
Not Available
Failure of a software assertion.
These are the repercussions of the alert being set
The door zero position is cleared.
The door zero position was cleared due to latch closing while door angle is above threshold value, the angle reaching threshold negative value, or the door controller resetting while latch is not closed. Alert payload data should provide more information on specific condition(s) involved.
The door power operation is disabled.
Not Available
NVRAM detected as corrupted.
These are the repercussions of the alert being set
The door latch transitions to opened state while the vehicle is in motion.
Latch status changes from closed to opened while the vehicle is in motion.
Door latch may be opened while vehicle is in motion, or the door latch is incorrectly detected open.
The door stopped unexpectedly while opening or closing.
The door controller detected a stopping condition while opening or closing. Alert payload data should provide more information on specific condition(s) involved.
Door opening or closing actuation did not complete.
The door motor brake is not calibrated and using default values.
Door motor brake has no calibration data and is using default values.
The door motor brake might not function as expected. Use Service action 'Write Actuator Brake Calibration' to add it.
The door controller's left or right side configuration is invalid or unspecified.
Door controller side configuration is not set, invalid, or cannot be determined by reading the dedicated harness pins. Alert payload data should provide more information on the specific condition(s) involved.
Door controller may not communicate and will not operate as expected. Run the correct 'Side Learn' action to configure it.