Alerts

Alerts

Signal Name Description Condition Impact Important
BCFPM_w040_MirrorMotor
setcondition
These are the repercussions of the alert being set
No
BCFPM_w039_MirrorMovement
Mirror failed to change movement states.
These are the repercussions of the alert being set
No
BCFPM_w032_WindowCommError
Lin frame error.
These are the repercussions of the alert being set
No
BCFPM_w031_WindowRegulator
Error from LIN.
The windows could be malfunctioning.
No
BCFPM_w057_ReflectorLamp
The desired state of the reflector lamp could not be set, the current state is not the expected one or the light did time out
These are the repercussions of the alert being set
No
BCFPM_w056_MirrorHeatError
Mirror heat enable failed
Mirror may not be heated when it should be
No
BCFPM_w030_LockedDoorOpened
Door state open and locked.
These are the repercussions of the alert being set
No
The door controller's left or right side configuration is invalid or unspecified.
Door controller side configuration is not set, invalid, or cannot be determined by reading the dedicated harness pins. Alert payload data should provide more information on the specific condition(s) involved.
Door controller may not communicate and will not operate as expected. Run the correct 'Side Learn' action to configure it.
No
Not Available
NVRAM detected as corrupted.
These are the repercussions of the alert being set
No
Not Available
Flash CRC is corrupted.
These are the repercussions of the alert being set
No
Not Available
Any of the signals in message RCM are set.
These are the repercussions of the alert being set
No
Not Available
setcondition
These are the repercussions of the alert being set
No
Not Available
setcondition
These are the repercussions of the alert being set
No
The log data contains failure count and up to five init failure codes.
A task init function returns with an error.
If an init routine fails, software may not opperate correctly.
No
Not Available
setcondition
These are the repercussions of the alert being set
No
Not Available
setcondition
These are the repercussions of the alert being set
No
Not Available
setcondition
These are the repercussions of the alert being set
No
Not Available
Reasons to keep the controller awake have been the same for greater than one hour
The bus could not sleep causing significant range loss for the battery pack
No
Not Available
A signal is received 10% out of timing 3 times in a row.
These are the repercussions of the alert being set
No
After a record upgrade is successful, resetting the ECU should clear the alert.
Record not found, CRC mismatch, Version mismatch, Version upgrade.
Indicate the state of non-volatile data in the ECU.
No