Alerts

Alerts

Signal Name Description Condition Impact Important
Not Available
Failure of a software assertion.
These are the repercussions of the alert being set
No
Undervoltage detection by the CPU can set this alert.
Sudden power loss.
These are the repercussions of the alert being set
No
This message contains separate signals for each watchdog reset source.
A watchdog (external or internal) was not serviced in time.
These are the repercussions of the alert being set
No
Log contains stack usage for each task.
Stack usage exceeds 80% for any task.
Stack overflow can occur if there is not enough stack space.
No
Log contains CPU load for each task.
CPU load exceeds 80%.
High CPU load can indicate ineffecient code.
No
Production vehicle should not have Debug Jumper in place. Remove jumper from ECU.
ECU Debug Jumper is set.
ECU Debug Jumper will disable SBC watchdog, preventing external watchdog reset protection.
No
BCFPM_w091_CrashStateMismatch
BDY_RCM_collision did not match BDY_BCCEN_collision
If any crash signal is active, crash behavior is active
No
BCFPM_w090_CrashUnlockError
Vehicle did not unlock after crash.
These are the repercussions of the alert being set
No
BCFPM_w086_badESPData
the ESP values are greater than 9.8 m/s
Engineering debug alert only
No
BCFPM_w085_ESPGyroUnstable
the ESP has shutdown before stable acceleration values could be captured
Engineering debug alert only
No
The door stopped unexpectedly while opening or closing.
The door controller detected a stopping condition while opening or closing. Alert payload data should provide more information on specific condition(s) involved.
Door opening or closing actuation did not complete.
No
This alert helps to indicate if the latch has water ingress which has damaged or caused undesired behaviors for the vehicle.
While the vehicle is moving, latch status changes from CLOSED to OPENED.
Door may be unlatched while vehicle is in motion.
No
BCFPM_w080_CurrentDropOut
A significant drop in current is seen while actuator is being driven
Actuator will temporarily not respond to being driven
No
Not Available
setcondition
These are the repercussions of the alert being set
No
Need to save PFD actuator-specific calibration values into NVRAM via Toolbox
Door brake data is using default values
The door brake hold force may be wrong
No
The door zero position is cleared.
The door zero position was cleared due to latch closing while door angle is above threshold value, the angle reaching threshold negative value, or the door controller resetting while latch is not closed. Alert payload data should provide more information on specific condition(s) involved.
The door power operation is disabled.
No
BCFPM_w076_DoorIceBreakerFailure
Ice breaker has pulled home but the latch is not open
-
No
BCFPM_w075_DoorIceBreakerAttempt
In initial ice breaking state
-
No
The Body Controller Front Driver Door (BCFDM) or Body Controller Front Passenger Door (BCFPM) detects latch is not fully closed after ramping.
The BCFDM or BCFPM detects latch is not fully closed after ramping. The BCFPM detects latch is not fully closed after ramping.
Door will not close properly. If vehicle is locked, alarm may sound.
No
BCFPM_w073_UnexpectLatchOpen
Latch reported open or ajar but PFD is actually closed
-
No