| Signal Name | Description | Condition | Impact | Important |
|---|---|---|---|---|
|
This alert is reported by the TemperatureDiagnostics_Actuator_R12 (TDA) component when there is a power module overtemperature. Degradation parameters/estimator shall be checked, if those are correct, HW failure.
|
EPAS application actuator temperature diagnostics detected overtemperature (power module).
|
EPAS full loss of assist.
|
No
|
|
|
This alert is reported by the ActuatorManager_R12 (AM) component when the external operating condition change.
|
-
|
EPAS full loss of assist.
|
No
|
|
|
This alert is reported by the ActuatorManager_R12 (AM) component when the external operating condition change.
|
If requested actuator control state changes to ACT_EMERGENCY_OFF_REVERSIBLE.
|
EPAS full loss of assist.
|
No
|
|
|
This alert is reported when there is a battery fet failure or DC link capacitor failure. Reported at runtime.
|
EPAS detected battery fet or DC link capacitor failure at runtime.
|
EPAS full loss of assist.
|
No
|
|
|
This alert is reported by the BlackoutTimeAndResetCounter_R12 (BTARC) component when analog restart timer is working incorrectly. This diagnostic checks if the analog restart timer is working correctly.
|
EPAS application BTARC management failure (timer restart).
|
EPAS will not attempt fast restart.
|
No
|
|
|
This alert is reported by the MCURamInit_TC3x (MRI) component when the memory initialization is failed when initializing the peripheral RAM instances.
|
EPAS application memory initialization failed (peripheral RAM).
|
EPAS reset. If reset more than 6 then EPAS fallback to bootloader.
|
No
|
|
|
This alert is reported by the MCURamInit_TC3x (MRI) component when the memory initialization is failed when initializing the core RAM instances.
|
EPAS application memory initialization failed (core RAM).
|
EPAS reset. If reset more than 6 then EPAS fallback to bootloader.
|
No
|
|
|
This alert is reported if (DC Link capacitor temperature higher than limit or not available) for at least debounce limit long time. The error is cleared, if the temperature is below the overtemp threshold, and its qualifier is RELIABLE for long enough.
|
EPAS application diagnostics detected overtemperature (CMC EMI filter).
|
EPAS full loss of assist.
|
No
|
|
|
This alert is reported if (DC Link capacitor temperature higher than limit or not available) for at least debounce limit long time. The alert is cleared, if the temperature is below the overtemp threshold, and its qualifier is RELIABLE for long enough.
|
EPAS application diagnostics detected overtemperature (DMC EMI filter).
|
EPAS full loss of assist.
|
No
|
|
|
This alert is reported when Bridge FET short may be present.
|
EPAS application diagnostics detected bridge fet short.
|
EPAS full loss of assist.
|
No
|
|
|
This alert is reported in case of an Inter-MCU configuration mismatch between two ECU side.
|
EPAS detected configuration mismatch between two ECU side.
|
EPAS full loss of assist.
|
No
|
|
|
This alert is reported when at startup, before reporting the previous error with the reset reaction, ErrorHook was called again because of an error in a partition which is configured to handle such errors with immediate safety reset. This error ID will show the last problem which caused the invocation of the ErrorHook with reset as the partition reaction.
|
ErrorHook was called again because of an error in a partition which is configured to handle such errors with immediate safety reset.
|
EPAS reset.
|
No
|
|
|
This alert is reported by the ExceptionHandler_TC3x (EXCH) component when there is a single-bit or multi-bit (all 1 and all 0) error in the pflash. This diagnostic is the handling of the exception thrown by the PFlash ECC when it encountered a multi-bit Flash fault.
|
When PFlash ECC encountered a multi-bit Flash fault. EPAS application component ExceptionHandler detected unrecoverable memory failure (PFlash ECC fault).
|
EPAS reset.
|
No
|
|
|
This alert is reported by the OsErrorHandler_R12(OSEH) component when before reporting the previous error, ErrorHook was called again because of an error in a partition which is configured to handle such errors without requesting immediate safety reset.
|
If any OS service returns a StatusType value other value than E_OK. Reported if while processing OS error occurred in QM partition one more OS error is detected.
|
EPAS reset.
|
No
|
|
|
This alert is reported by the StartupCauseProvider_R12 (SCP) component if it determines that the startup cause is a safety reset.
|
EPAS determined that the startup cause is a safety reset.
|
No impact
|
No
|
|
|
This alert is reported by the OsErrorHandler_R12(OSEH) component when ErrorHook was called because of an error in a partition which is configured to handle such errors without requesting immediate safety reset.
|
If any OS service returns a StatusType value other value than E_OK. Reported if OS error occurred in QM partition. It's a reversible error that is reported upon detection of OS error and immediately cleared to catch and indicate further errors
|
EPAS reset.
|
No
|
|
|
This alert is reported by the FrequencyTransformer_R12 (FT) component when the electrical angle QoS is Substitute Value or Error and RotorPositionAge tolerance time elapsed. This diagnostic compares the 2 local RPSs, and compares the local RPSs and the remote one. If no RPS is available or it is not decidable which RPS is usable, it signals this.
|
Electrical angle QoS is Substitute Value or Error and RotorPositionAge tolarence time elapsed.
|
Unreliable absolute steering position provision qualifier. Virtual End Lock deactivation.
|
No
|
|
|
This alert is reported by the TemperatureModelPSFETJunction (TMPSFETJ) components when checking overflow of possible values of estimated temperatures. Possible values are calculated according to defined data constraints.
|
Overflow of possible values of estimated temperatures.
|
EPAS uses not reliable estimations for temperature.
|
No
|
|
|
This alert is reported by the OsErrorHandler_R12(OSEH) component when ErrorHook was called because of an error in a partition which is configured to handle such errors with requesting a guarded reset. This error is reported after the guarded reset.
|
If any OS service returns a StatusType value other value than E_OK. The error is reported after a guarded reset caused by OS error.
|
EPAS reset.
|
No
|
|
|
This alert is reported by the ExceptionHandler_TC3x (EXCH) component when exception with reset before the previous similar error was reported. The alert is reported after reset if several exceptions in ASIL D partition were caught before reset.
|
EPAS application component ExceptionHandler detected additional exceptions in ASIL D partition after a reset.
|
EPAS reset
|
No
|