| Signal Name | Description | Condition | Impact |
|---|---|---|---|
|
Negative contactor opened unexpectedly due to insufficient coil drive current.
|
Contactor state exited ECONOMIZED because coil current was too low.
|
Vehicle may lose propulsion or be unable to support LV system.
|
|
|
High-side pyro high-side switch (SF FET) is non-functional.
|
High-side pyro-P voltage does not rise to within a margin of the energy reserve voltage when the SF FET is enabled.
|
High-side pack High Voltage will be blocked, charge and drive may be unavailable.
|
|
|
High-side pyro squib failed the resistance test.
|
The high-side pyro failed the resistance test by entering an invalid case, indicating that the pyro circuit is compromised and needs to be replaced.
|
High-side pack High Voltage will be blocked, charge and drive may be unavailable.
|
|
|
High-side pyro leakage current exceeds tolerance shortly following the resistance test.
|
High-side pyro leakage current exceeds tolerance shortly following the resistance test.
|
This alert is primarily informational and for logging purposes. No expected impact on vehicle functionality.
|
|
|
High-side pyro leakage current exceeds tolerance shortly following the low-side switch (SR FET) test.
|
High-side pyro leakage current exceeds tolerance shortly following the SR FET test.
|
High-side pack High Voltage will be blocked, charge and drive may be unavailable.
|
|
|
High-side pyro leakage current exceeds tolerance shortly following the high-side switch (SF FET) test.
|
High-side pyro leakage current exceeds tolerance shortly following the SF FET test.
|
High-side pack High Voltage will be blocked, charge and drive may be unavailable.
|
|
|
High-side pyro leakage current exceeds tolerance.
|
High-side pyro leakage current exceeds tolerance.
|
High-side pack High Voltage will be blocked, charge and drive may be unavailable.
|
|
|
The low-side pyro was deployed, and the duration of the deployment pulse was measured.
|
The low-side pyro was either actively or passively deployed.
|
This alert is primarily informational and for logging purposes. No expected impact on vehicle functionality.
|
|
|
The low-side pyro was deployed by the low-side passive pyro circuit.
|
Firmware detects that the low-side passive pyro circuit is actively deploying the low-side pyro.
|
Low-side pack High Voltage will be blocked, charge and drive may be unavailable.
|
|
|
The low-side pyro was deployed by firmware.
|
The low-side pyro was deployed by firmware.
|
Low-side pack High Voltage will be blocked, charge and drive may be unavailable.
|
|
|
There was an attempt to deploy the low-side pyro, but it was unsuccessful.
|
The firmware could not successfully trigger a low-side pyro deployment or there was an attempt to deploy the low-side pyro while the deployed test was actively running for the low-side pyro.
|
The vehicle may not drive or charge.
|
|
|
Low-side pyro squib resistance is too low.
|
The measured resistance between low-side pyro-P and pyro-N is lower than the minimum limit.
|
Low-side pack High Voltage will be blocked, charge and drive may be unavailable.
|
|
|
Low-side pyro squib resistance is too high.
|
The measured resistance between low-side pyro-P and pyro-N is higher than the maximum limit.
|
Low-side pack High Voltage will be blocked, charge and drive may be unavailable.
|
|
|
Low-side pyro squib is open circuit.
|
The measured resistance between low-side pyro-P and pyro-N is saturated.
|
Low-side pack will not be able to come online.
|
|
|
Low-side pyro low-side switch (SR FET) is non-functional.
|
Low-side pyro-P voltage does not rise to within a margin of the energy reserve voltage when the SR FET is enabled.
|
Low-side pack High Voltage will be blocked, charge and drive may be unavailable.
|
|
|
Low-side pyro high-side switch (SF FET) is non-functional.
|
Low-side pyro-P voltage does not rise to within a margin of the energy reserve voltage when the SF FET is enabled.
|
Low-side pack High Voltage will be blocked, charge and drive may be unavailable.
|
|
|
Low-side pyro squib failed the resistance test.
|
The low-side pyro failed the resistance test by entering an invalid case, indicating that the pyro circuit is compromised and needs to be replaced.
|
Low-side pack High Voltage will be blocked, charge and drive may be unavailable.
|
|
|
Low-side pyro leakage current exceeds tolerance shortly following the resistance test.
|
Low-side pyro leakage current exceeds tolerance shortly following the resistance test.
|
This alert is primarily informational and for logging purposes. No expected impact on vehicle functionality.
|
|
|
A battery pack 2 module temperature is above the fault temperature limit
|
A battery pack 2 module temperature is above the fault temperature limit for X duration (in seconds)
|
Power/drive limits may be reduced
|
|
|
A battery pack 1 module temperature is above the fault temperature limit
|
A battery pack 1 module temperature is above the fault temperature limit for X duration (in seconds)
|
Power/drive limits may be reduced
|