Alerts

Alerts

Signal Name Description Condition Impact
A battery pack 1 brick voltage is below the open circuit voltage (OCV) undervoltage limit at rest.
A battery pack 1 brick voltage is below the under voltage OCV limit for X duration (in seconds) while contactors are open.
Drive may be blocked.
Positive contactor opened unexpectedly due to insufficient coil drive current.
Contactor state exited ECONOMIZED because coil current was too low.
Vehicle may lose propulsion or be unable to support LV system.
A battery pack 2 brick voltage is below the under voltage fault limit.
A battery pack 2 brick voltage is below the under voltage fault limit for X duration (in seconds)
Inability to enter drive or support the low voltage (LV) system
A battery pack 1 brick voltage is below the under voltage fault limit.
A battery pack 1 brick voltage is below the under voltage fault limit for X duration (in seconds)
Inability to enter drive or support the low voltage (LV) system
Tried to close negative contactor but failed because a voltage match was not maintained.
Contactor state timed out of PULLED_IN because a voltage match was not maintained.
Negative pack contactor will remain open.
A battery pack 2 brick voltage is below the over discharged voltage limit.
A battery pack 2 brick voltage is below the over discharged voltage limit for X duration (in seconds)
The vehicle will not drive or charge.
A battery pack 1 brick voltage is below the over discharged voltage limit.
A battery pack 1 brick voltage is below the over discharged voltage limit for X duration (in seconds)
The vehicle may not drive.
Tried to close positive contactor but failed because a voltage match was not maintained.
Contactor state timed out of PULLED_IN because a voltage match was not maintained.
Positive pack contactor will remain open.
A battery pack 2 brick voltage is above the fault voltage limit.
A battery pack 2 brick voltage is above the fault voltage limit for X duration (in seconds)
The vehicle may not drive or charge.
A battery pack 1 brick voltage is above the fault voltage limit.
A battery pack 1 brick voltage is above the fault voltage limit for X duration (in seconds)
The vehicle may not drive or charge.
Tried to close negative contactor but failed because the coil drive current was too low.
Contactor state timed out of PULLED_IN because of insufficient contactor coil current.
Negative pack contactor will remain open.
Tried to close positive contactor but failed because the coil drive current was too low.
Contactor state timed out of PULLED_IN because of insufficient contactor coil current.
Positive pack contactor will remain open.
Did not try to close negative contactor because a voltage match was not achieved.
Contactor state is OPEN and the PULLED_IN state has been blocked for more than 10s because a required HV voltage match has not been achieved.
Negative pack contactor will remain open.
Did not try to close positive contactor because a voltage match was not achieved.
Contactor state is OPEN and the PULLED_IN state has been blocked for more than 10s because a required HV voltage match has not been achieved.
Positive pack contactor will remain open.
Indicates a Battery Monitoring Board (BMB) reference voltage has continuously been out of bounds.
Any BMB reference voltage has continuously deviated outside the in-bounds threshold of the nominal voltage
Other BMB voltage signals will be substituted given the reference voltage is unreliable
Indicates valid data is missing for one or more stack voltages.
One or more stack voltages are continuously detected as invalid
Stack voltage data is likely being substituted to replace invalid readings
Indicates valid data is missing for one or more brick voltages.
One or more brick voltages are continuously detected as invalid
Brick voltage data is likely being substituted to replace invalid readings
FC contactor opened unexpectedly due to insufficient contactor drive voltage.
Contactor control state exited CLOSED because of insufficient contactor power voltage.
Vehicle will stop charging.
Contactor opened unexpectedly due to insufficient contactor drive voltage.
Contactor control state exited CLOSED because of insufficient contactor power voltage.
Vehicle may lose propulsion or be unable to support LV system.
FC contactor exited the economized state unexpectedly. Possibly insufficient coil drive current.
Contactor control state exited CLOSED because either of the contactors exited ECONOMIZED.
Vehicle will stop charging.