HVBATT_a096_LsPyroSquibOpen

Description

Low-side pyro squib is open circuit.

Condition

The measured resistance between low-side pyro-P and pyro-N is saturated.

Clear Condition

The measured resistance between low-side pyro-P and pyro-N is not saturated.

Potential Impact

Low-side pack will not be able to come online.

Customer Facing Message 1

Not Available

Customer Facing Message 2

Not Available

Audiences

service

Models

Cybertruck