| Signal Name | Description | Condition | Impact |
|---|---|---|---|
|
A battery pack 2 module temperature is above the warning temperature limit
|
A battery pack 2 module temperature is above the warning temperature limit for X duration (in seconds)
|
Power/drive limits may be reduced
|
|
|
A battery pack 1 module temperature is above the warning temperature limit
|
A battery pack 1 module temperature is above the warning temperature limit for X duration (in seconds)
|
Power/drive limits may be reduced
|
|
|
A battery pack 2 brick voltage is below the under voltage fault limit
|
A battery pack 2 brick voltage is below the under voltage fault limit for X duration (in seconds)
|
Inability to enter drive or support the low voltage (LV) system
|
|
|
A battery pack 1 brick voltage is below the under voltage fault limit
|
A battery pack 1 brick voltage is below the under voltage fault limit for X duration (in seconds)
|
Inability to enter drive or support the low voltage (LV) system
|
|
|
A battery pack 2 brick voltage is below the over discharged voltage limit
|
A battery pack 2 brick voltage is below the over discharged voltage limit for X duration (in seconds)
|
The vehicle will not drive or charge.
|
|
|
Positive contactor was blocked from opening due to high current. Pyro deployed instead.
|
High voltage current is too high while attempting to open the contactor.
|
The positive pyro fuse will be deployed.
|
|
|
Low-side pyro leakage current exceeds tolerance shortly following the low-side switch (SR FET) test.
|
Low-side pyro leakage current exceeds tolerance shortly following the SR FET test.
|
Low-side pack High Voltage will be blocked, charge and drive may be unavailable.
|
|
|
Low-side pyro leakage current exceeds tolerance shortly following the high-side switch (SF FET) test.
|
Low-side pyro leakage current exceeds tolerance shortly following the SF FET test.
|
Low-side pack High Voltage will be blocked, charge and drive may be unavailable.
|
|
|
Low-side pyro leakage current exceeds tolerance.
|
Low-side pyro leakage current exceeds tolerance.
|
Low-side pack High Voltage will be blocked, charge and drive may be unavailable.
|
|
|
The pyro circuit is bad. Replace the High Voltage Controller (HVC).
|
A pyro circuit diagnostic failed.
|
One or more of the half packs will not be able to come online.
|
|
|
Replace the high-side pack pyro.
|
The high-side pyro squib is open circuit.
|
The high-side half of the pack is not able to come online.
|
|
|
Replace the low-side pack pyro.
|
The low-side pyro squib is open circuit.
|
The low-side half of the pack is not able to come online.
|
|
|
A battery pack 2 brick voltage is below the open circuit voltage (OCV) undervoltage limit at rest.
|
A battery pack 2 brick voltage is below the under voltage OCV limit for X duration (in seconds) while contactors are open.
|
Drive may be blocked.
|
|
|
A battery pack 1 brick voltage is below the open circuit voltage (OCV) undervoltage limit at rest.
|
A battery pack 1 brick voltage is below the under voltage OCV limit for X duration (in seconds) while contactors are open.
|
Drive may be blocked.
|
|
|
Positive contactor opened unexpectedly due to insufficient coil drive current.
|
Contactor state exited ECONOMIZED because coil current was too low.
|
Vehicle may lose propulsion or be unable to support LV system.
|
|
|
Tried to close negative contactor but failed because a voltage match was not maintained.
|
Contactor state timed out of PULLED_IN because a voltage match was not maintained.
|
Negative pack contactor will remain open.
|
|
|
A battery pack 2 brick voltage is above the fault voltage limit
|
A battery pack 2 brick voltage is above the fault voltage limit for X duration (in seconds)
|
The vehicle may not drive or charge.
|
|
|
A battery pack 1 brick voltage is above the fault voltage limit
|
A battery pack 1 brick voltage is above the fault voltage limit for X duration (in seconds)
|
The vehicle may not drive or charge.
|
|
|
Indicates valid data is missing for one or more stack voltages
|
One or more stack voltages are continuously detected as invalid
|
Stack voltage data is likely being substituted to replace invalid readings
|
|
|
Negative contactor was blocked from opening due to high current. Pyro deployed instead.
|
High voltage current is too high while attempting to open the contactor.
|
The negative pyro fuse will be deployed.
|