| Signal Name | Description | Condition | Impact |
|---|---|---|---|
|
The High Voltage Battery (HVBATT) detects the Charge Port High Voltage Interlock Loop (CPIL) is open.
|
The HVBATT has detected that CPIL is open.
|
The vehicle may be unable to charge.
|
|
|
Low-side shunt bar temperature is too low
|
Low-side shunt bar temperature is too low
|
This alert is primarily informational and is used for logging purposes. No expected impact on vehicle functionality.
|
|
|
Low-side shunt active sense and passive sense readings are not in agreement
|
Low-side shunt active sense and passive sense readings have a delta outside of the acceptable margin
|
Low-side sub pack may not come online
|
|
|
Low-side shunt active sense current reading deviates from zero when contactors are open
|
Contactors are open and low-side shunt active sense reading is larger than acceptable margin
|
This alert is primarily informational and is used for logging purposes. No expected impact on vehicle functionality.
|
|
|
A brick voltage is above the fault voltage limit
|
A brick voltage is above the fault voltage limit for X duration (in seconds)
|
The vehicle may not drive or charge.
|
|
|
The configured battery pack 1 passive pyro setpoint is invalid
|
The configured battery pack 1 passive pyro setpoint is invalid
|
Vehicle performance may be reduced
|
|
|
Low-side shunt detects shunt connector as disconnected
|
Low-side shunt active current reads 0A, passive current reflects open circuit conditions
|
Low-side sub pack may not come online
|
|
|
Incorrect or Missing configuration block programmed
|
ECU config block may be missing, incorrect, or unsupported
|
ECU is unable to initialize configuration parameters
|
|
|
The low-side shunt measurement asic has a SPI communication fault or other internal fault
|
Fault condition was set during SPI communications
|
Low-side shunt readings are stale
|
|
|
Low-side shunt bar temperature is too high
|
Low-side shunt bar temperature is too high
|
Low-side pack HV will be blocked. The shunt may become physically damaged.
|
|
|
Data integrity loss due to Battery Monitoring Board (BMB) chain double break
|
A prolonged communication issue with the BMB daisy chain that is known to cause a loss of BMB sensor data is detected
|
BMB sensor data is likely being substituted to replace data missing due to the communication issue
|
|
|
Measurement of internal isolation (within the pack) is too low
|
Internal isolation is measured to be below the alert threshold
|
Pack may not come online
|
|
|
Indicates valid data is missing for one or more brick voltages
|
One or more brick voltages are continuously detected as invalid
|
Brick voltage data is likely being substituted to replace invalid readings
|
|
|
Indicates a Battery Monitoring Board (BMB) reference voltage has continuously been out of bounds
|
Any BMB reference voltage has continuously deviated outside the in-bounds threshold of the nominal voltage
|
Other BMB voltage signals will be substituted given the reference voltage is unreliable
|
|
|
A battery pack 1 brick voltage is below the over discharged voltage limit
|
A battery pack 1 brick voltage is below the over discharged voltage limit for X duration (in seconds)
|
The vehicle may not drive.
|
|
|
The BMS has detected isolation failure conditions in several drive sessions
|
Isolation or isolation degradation alert is set in several drive sessions
|
Vehicle may be unable to restart
|
|
|
High-side pyro squib resistance is too high.
|
The measured resistance between high-side pyro-P and pyro-N is higher than the maximum limit.
|
High-side pack High Voltage will be blocked, charge and drive may be unavailable.
|
|
|
High-side pyro squib is open circuit.
|
The measured resistance between high-side pyro-P and pyro-N is saturated.
|
High-side pack will not be able to come online.
|
|
|
Positive contactor is expected to be open but the voltage match remains. Possible weld detected.
|
Contactor state timed out of OPENING (and transitioned to AUX_MISMATCH) due to a weld not having been disqualified.
|
The pyro fuse may be deployed.
|
|
|
High-side pyro low-side switch (SR FET) is non-functional.
|
High-side pyro-P voltage does not rise to within a margin of the energy reserve voltage when the SR FET is enabled.
|
High-side pack High Voltage will be blocked, charge and drive may be unavailable.
|