| Signal Name | Description | Condition | Impact |
|---|---|---|---|
|
Subpack measurement of internal isolation (within the subpack) is too low.
|
Internal isolation is measured to be below the alert threshold
|
Subpack may not come online
|
|
|
A pack module temperature is above maximum temperature limit.
|
A pack module temperature is above maximum temperature limit for X duration (in seconds)
|
The conactors may open immdediately or pyro disconnect may blow
|
|
|
A brick voltage is below minimum voltage limit.
|
A brick voltage is below minimum voltage limit for X duration (in seconds)
|
The conactors may open immdediately or pyro disconnect may blow
|
|
|
A brick voltage is above maximum voltage limit.
|
A brick voltage is above maximum voltage limit
|
The contactors may open immediately or pyro disconnect may blow
|
|
|
Incorrect, missing, or unsupported board part number programmed.
|
HVPACK detects an unexpected board part number
|
HVPACK is unable to initialize parameters related to printed circuit board assembly (PCBA) configuration
|
|
|
Incorrect or Missing configuration block programmed.
|
HVPACK config block may be missing, incorrect, or unsupported
|
HVPACK is unable to initialize configuration parameters
|
|
|
High Voltage Battery Pack (HVPACK) reports the shunt bar temperature is lower than expected.
|
Shunt bar temperature is outside the expected threshold.
|
This alert is primarily informational and is used for logging purposes.
|
|
|
Negative contactor is expected to be open but HV current is still present. Possible weld detected.
|
Contactor state timed out of OPENING (and transitioned to AUX_MISMATCH) due to HV current not being low enough to open contactors.
|
The pyro fuse may be deployed.
|
|
|
Positive contactor is expected to be open but HV current is still present. Possible weld detected.
|
Contactor state timed out of OPENING (and transitioned to AUX_MISMATCH) due to HV current not being low enough to open contactors.
|
The pyro fuse may be deployed.
|
|
|
Negative contactor is expected to be open but the voltage match remains. Possible weld detected.
|
Contactor state timed out of OPENING (and transitioned to AUX_MISMATCH) due to a weld not having been disqualified.
|
The pyro fuse may be deployed.
|
|
|
Positive contactor is expected to be open but the voltage match remains. Possible weld detected.
|
Contactor state timed out of OPENING (and transitioned to AUX_MISMATCH) due to a weld not having been disqualified.
|
The pyro fuse may be deployed.
|
|
|
Negative contactor is expected to be open but aux reports them as still closed.
|
Contactor state timed out of the OPENING state (and transitioned to AUX_MISMATCH) due to aux reporting the contactor as still closed.
|
Firmware will try to open the contactor again.
|
|
|
Positive contactor is expected to be open but aux reports them as still closed.
|
Contactor state timed out of the OPENING state (and transitioned to AUX_MISMATCH) due to aux reporting the contactor as still closed.
|
Firmware will try to open the contactor again.
|
|
|
Negative contactor was blocked from opening due to high current. Pyro deployed instead.
|
High voltage current is too high while attempting to open the contactor.
|
The negative pyro fuse will be deployed.
|
|
|
Positive contactor was blocked from opening due to high current. Pyro deployed instead.
|
High voltage current is too high while attempting to open the contactor.
|
The positive pyro fuse will be deployed.
|
|
|
Negative contactor opened unexpectedly due to insufficient coil drive current.
|
Contactor state exited ECONOMIZED because coil current was too low.
|
Vehicle may lose propulsion or be unable to support LV system.
|
|
|
Positive contactor opened unexpectedly due to insufficient coil drive current.
|
Contactor state exited ECONOMIZED because coil current was too low.
|
Vehicle may lose propulsion or be unable to support LV system.
|
|
|
Tried to close negative contactor but failed because a voltage match was not maintained.
|
Contactor state timed out of PULLED_IN because a voltage match was not maintained.
|
Negative pack contactor will remain open.
|
|
|
Tried to close positive contactor but failed because a voltage match was not maintained.
|
Contactor state timed out of PULLED_IN because a voltage match was not maintained.
|
Positive pack contactor will remain open.
|
|
|
Tried to close negative contactor but failed because the coil drive current was too low.
|
Contactor state timed out of PULLED_IN because of insufficient contactor coil current.
|
Negative pack contactor will remain open.
|