Signal Name Description Condition Impact
Subpack measurement of internal isolation (within the subpack) is too low.
Internal isolation is measured to be below the alert threshold
Subpack may not come online
A pack module temperature is above maximum temperature limit.
A pack module temperature is above maximum temperature limit for X duration (in seconds)
The conactors may open immdediately or pyro disconnect may blow
A brick voltage is below minimum voltage limit.
A brick voltage is below minimum voltage limit for X duration (in seconds)
The conactors may open immdediately or pyro disconnect may blow
A brick voltage is above maximum voltage limit.
A brick voltage is above maximum voltage limit
The contactors may open immediately or pyro disconnect may blow
Incorrect, missing, or unsupported board part number programmed.
HVPACK detects an unexpected board part number
HVPACK is unable to initialize parameters related to printed circuit board assembly (PCBA) configuration
Incorrect or Missing configuration block programmed.
HVPACK config block may be missing, incorrect, or unsupported
HVPACK is unable to initialize configuration parameters
High Voltage Battery Pack (HVPACK) reports the shunt bar temperature is lower than expected.
Shunt bar temperature is outside the expected threshold.
This alert is primarily informational and is used for logging purposes.
Negative contactor is expected to be open but HV current is still present. Possible weld detected.
Contactor state timed out of OPENING (and transitioned to AUX_MISMATCH) due to HV current not being low enough to open contactors.
The pyro fuse may be deployed.
Positive contactor is expected to be open but HV current is still present. Possible weld detected.
Contactor state timed out of OPENING (and transitioned to AUX_MISMATCH) due to HV current not being low enough to open contactors.
The pyro fuse may be deployed.
Negative contactor is expected to be open but the voltage match remains. Possible weld detected.
Contactor state timed out of OPENING (and transitioned to AUX_MISMATCH) due to a weld not having been disqualified.
The pyro fuse may be deployed.
Positive contactor is expected to be open but the voltage match remains. Possible weld detected.
Contactor state timed out of OPENING (and transitioned to AUX_MISMATCH) due to a weld not having been disqualified.
The pyro fuse may be deployed.
Negative contactor is expected to be open but aux reports them as still closed.
Contactor state timed out of the OPENING state (and transitioned to AUX_MISMATCH) due to aux reporting the contactor as still closed.
Firmware will try to open the contactor again.
Positive contactor is expected to be open but aux reports them as still closed.
Contactor state timed out of the OPENING state (and transitioned to AUX_MISMATCH) due to aux reporting the contactor as still closed.
Firmware will try to open the contactor again.
Negative contactor was blocked from opening due to high current. Pyro deployed instead.
High voltage current is too high while attempting to open the contactor.
The negative pyro fuse will be deployed.
Positive contactor was blocked from opening due to high current. Pyro deployed instead.
High voltage current is too high while attempting to open the contactor.
The positive pyro fuse will be deployed.
Negative contactor opened unexpectedly due to insufficient coil drive current.
Contactor state exited ECONOMIZED because coil current was too low.
Vehicle may lose propulsion or be unable to support LV system.
Positive contactor opened unexpectedly due to insufficient coil drive current.
Contactor state exited ECONOMIZED because coil current was too low.
Vehicle may lose propulsion or be unable to support LV system.
Tried to close negative contactor but failed because a voltage match was not maintained.
Contactor state timed out of PULLED_IN because a voltage match was not maintained.
Negative pack contactor will remain open.
Tried to close positive contactor but failed because a voltage match was not maintained.
Contactor state timed out of PULLED_IN because a voltage match was not maintained.
Positive pack contactor will remain open.
Tried to close negative contactor but failed because the coil drive current was too low.
Contactor state timed out of PULLED_IN because of insufficient contactor coil current.
Negative pack contactor will remain open.