The brake booster (IBST) does not receive a message from the Electronic Stability Program (ESP) within the expected time frame.
IBST does not receive a message from the ESP over Party CAN within the expected time frame.
IBST may not operate as expected.
iBooster (IBST) detected Differential Travel Sensor (DTS) offset is confirmed too high.
IBST detected DTS offset is confirmed too high.
IBST may not operate as expected.
iBooster (IBST) detected Differential Travel Sensor (DTS) offset is too low.
IBST detects DTS offset is too low.
IBST may not operate as expected.
iBooster (IBST) detected deviation between differential travel signal channel 1 and 2 is out of functional range.
IBST detected deviation between differential travel signal channel 1 and 2 is out of functional range.
IBST may not operate as expected.
iBooster (IBST) detected the differential travel signal (channel 1) is out of functional range (high).
IBST detected the differential travel signal (channel 1) is out of functional range (high).
IBST may not operate as expected.
iBooster (IBST) detected the differential travel signal (channel 1) is out of functional range (low).
IBST detected the differential travel signal (channel 1) is out of functional range (low).
IBST may not operate as expected.
iBooster (IBST) detected a load dump event before or during Bridge Main Switch (BMS) Fail Safe Logic Test (FSLT).
IBST detected a load dump event before or during BMS FSLT.
IBST may not operate as expected.
iBooster (IBST) detected a timeout event during brushless motor (BLM) initialization tests.
IBST detected a timeout event during BLM initialization tests.
IBST may not operate as expected.
iBooster (IBST) detected phase current 2 out of range (low).
IBST detected phase current 2 out of range (low).
IBST may not operate as expected.
iBooster (IBST) detected phase current 1 out of range (low).
IBST detected phase current 1 out of range (low).
IBST may not operate as expected.
Bosch DTC value: 0x00002100
-
iBooster (IBST) detected phase current 2 out of range (high).
IBST detected phase current 2 out of range (high).
IBST may not operate as expected.
iBooster (IBST) detected phase current 1 out of range (high).
IBST detected phase current 1 out of range (high).
IBST may not operate as expected.
Bosch DTC value: 0x00006200
-
iBooster (IBST) detected motor is temporarily unavailable due to reinitialization of bridge driver.
IBST detected motor is temporarily unavailable due to reinitialization of bridge driver.
IBST may not operate as expected.
iBooster (IBST) detected Rotation Position Sensor (RPS) raw signals (sine and cosine): Vector length oscillating.
IBST detected RPS raw signals (sine and cosine): Vector length oscillating.
IBST may not operate as expected.
Bosch DTC value: 0x00007200
-
iBooster (IBST) detected Rotation Position Sensor (RPS) raw signals (sine and cosine): Vector length too low.
IBST detected RPS raw signals (sine and cosine): Vector length too low.
IBST may not operate as expected.
iBooster (IBST) detected Rotation Position Sensor (RPS) raw signals (sine and cosine): Vector length too high.
IBST detected RPS raw signals (sine and cosine): Vector length too high.
IBST may not operate as expected.
iBooster (IBST) detected inconsistent Rotation Position Sensor (RPS) calibration data version compared to version in software.
IBST detected inconsistent RPS calibration data version compared to version in software.
IBST may not operate as expected.