| Signal Name | Description | Condition | Impact |
|---|---|---|---|
|
The pack side DCDC converter (DCDCA) lifetime energy record not ready for use
|
The lifetime energy record for DCDCA is not in an expected state
|
Lifetime energy conversion data for DCDCA cannot be stored
|
|
|
Non-Volatile Memory (NVM) record transfer channel stalled
|
The NVM sub-system becomes unresponsive to a read/write request
|
Some non-volatile data may not be stored and/or retrieved
|
|
|
DCAC converter A (DCACA) resonant tank calibration data is out of specification
|
A tank capacitance or inductance measurement for DCACA is not within the design margin
|
DCAC operation allowed with default resonant tank parameters at reduced surge current limit
|
|
|
The DC link side DCDC converter (DCDCB) resonant tank calibration data is out of specification
|
A tank capacitance or inductance measurement for DCDCB is not within the design margin
|
DCDC operation allowed with default resonant tank parameters, but risk of damaging the converter due to hard switching
|
|
|
The pack side DCDC converter (DCDCA) resonant tank calibration data is out of specification
|
A tank capacitance or inductance measurement for DCDCA is not within the design margin
|
DCDC operation allowed with default resonant tank parameters, but risk of damaging the converter due to hard switching
|
|
|
The Power Conversion System (PCS) detects an unknown grid configuration from the external charging equipment
|
The PCS detects unknown grid configuration
|
AC charging functionality may be unavailable
|
|
|
AC voltage is not present while the The Power Conversion System (PCS) is expecting AC voltage to be provided by the external charging equipment
|
The PCS does not detect AC input voltage while being commanded to charge
|
AC charging functionality may be unavailable
|
|
|
DCAC converter B (DCACB) is not operational
|
DCACB has exhausted all of its retries due to various conditions affecting functionality.
|
DCAC may be limited or unavailable.
|
|
|
The high voltage (HV) battery full voltage measurement is irrational
|
The HV battery full voltage is irrationally high or low
|
DCDC and DCAC may be limited or unavailable.
|
|
|
Sensor supply voltage outside of specificaiton
|
NA
|
Park assist functionality unavailable.
|
|
|
Undervoltage detected by the ECU
|
Sets when the ECU supply voltage is < 9V for 10 seconds or more.
|
None
|
|
|
This error is detected by the ECU. Sensor short to GND or short to plus or broken sensor line and all LIN errors
|
Five consequitive internal errors occured.
|
Sensor function will be impaired, park assist features will be disabled.
|
|
|
PARK_w022_S8_shortGround
|
|
-
|
|
|
Expected messages from RCM missing.
|
Messages missing for more than 3 nominal cycle times.
|
Some park assist functionality not availble
|
|
|
Expected messages from ESP missing.
|
Messages missing for more than 3 nominal cycle times.
|
Some park assist functionality not availble
|
|
|
Expected messages from EPB missing.
|
Messages missing for more than 3 nominal cycle times.
|
Some park assist functionality not availble
|
|
|
Expected messages from EPAS missing.
|
Messages missing for more than 3 nominal cycle times.
|
Some park assist functionality not availble
|
|
|
Expected messages from DI missing.
|
Messages missing for more than 3 nominal cycle times.
|
Some park assist functionality not availble
|
|
|
Expected messages from SCCM missing.
|
Messages missing for more than 3 nominal cycle times.
|
Some park assist functionality not availble
|
|
|
Expected messages from DAS/APP missing.
|
Messages missing for more than 3 nominal cycle times.
|
Some park assist functionality not availble
|