Alerts

Alerts

Signal Name Description Condition Impact
The pack side DCDC converter (DCDCA) lifetime energy record not ready for use
The lifetime energy record for DCDCA is not in an expected state
Lifetime energy conversion data for DCDCA cannot be stored
Non-Volatile Memory (NVM) record transfer channel stalled
The NVM sub-system becomes unresponsive to a read/write request
Some non-volatile data may not be stored and/or retrieved
DCAC converter A (DCACA) resonant tank calibration data is out of specification
A tank capacitance or inductance measurement for DCACA is not within the design margin
DCAC operation allowed with default resonant tank parameters at reduced surge current limit
The DC link side DCDC converter (DCDCB) resonant tank calibration data is out of specification
A tank capacitance or inductance measurement for DCDCB is not within the design margin
DCDC operation allowed with default resonant tank parameters, but risk of damaging the converter due to hard switching
The pack side DCDC converter (DCDCA) resonant tank calibration data is out of specification
A tank capacitance or inductance measurement for DCDCA is not within the design margin
DCDC operation allowed with default resonant tank parameters, but risk of damaging the converter due to hard switching
The Power Conversion System (PCS) detects an unknown grid configuration from the external charging equipment
The PCS detects unknown grid configuration
AC charging functionality may be unavailable
AC voltage is not present while the The Power Conversion System (PCS) is expecting AC voltage to be provided by the external charging equipment
The PCS does not detect AC input voltage while being commanded to charge
AC charging functionality may be unavailable
DCAC converter B (DCACB) is not operational
DCACB has exhausted all of its retries due to various conditions affecting functionality.
DCAC may be limited or unavailable.
The high voltage (HV) battery full voltage measurement is irrational
The HV battery full voltage is irrationally high or low
DCDC and DCAC may be limited or unavailable.
Sensor supply voltage outside of specificaiton
NA
Park assist functionality unavailable.
Undervoltage detected by the ECU
Sets when the ECU supply voltage is < 9V for 10 seconds or more.
None
This error is detected by the ECU. Sensor short to GND or short to plus or broken sensor line and all LIN errors
Five consequitive internal errors occured.
Sensor function will be impaired, park assist features will be disabled.
PARK_w022_S8_shortGround
-
Expected messages from RCM missing.
Messages missing for more than 3 nominal cycle times.
Some park assist functionality not availble
Expected messages from ESP missing.
Messages missing for more than 3 nominal cycle times.
Some park assist functionality not availble
Expected messages from EPB missing.
Messages missing for more than 3 nominal cycle times.
Some park assist functionality not availble
Expected messages from EPAS missing.
Messages missing for more than 3 nominal cycle times.
Some park assist functionality not availble
Expected messages from DI missing.
Messages missing for more than 3 nominal cycle times.
Some park assist functionality not availble
Expected messages from SCCM missing.
Messages missing for more than 3 nominal cycle times.
Some park assist functionality not availble
Expected messages from DAS/APP missing.
Messages missing for more than 3 nominal cycle times.
Some park assist functionality not availble