Alerts

Alerts

Signal Name Description Condition Impact Important
The planar transformer of DCAC converter B (DCACB) temperature is too high
DCACB planar transformer temperature exceeds the allowed temperature threshold
DCAC may be limited or unavailable.
No
The planar transformer of DCAC converter A (DCACA) temperature is too high
DCACA planar transformer temperature exceeds the allowed temperature threshold
DCAC may be limited or unavailable.
No
The DCDC ENABLE hard line functionality is disabled
The DCDC ENABLE line functionality is disabled
The high voltage battery controller (HVBATT) and vehicle controller (VC) cannot force shutdown DCDC by de-asserting the DCDC ENABLE line
No
The DCAC ENABLE hard line functionality is disabled
The DCAC ENABLE line functionality is disabled
The high voltage battery controller (HVBATT) cannot force shutdown DCAC by de-asserting the DCAC ENABLE line
No
The generated power rail (4.5V, 10V, or 18V) has gone lower than the allowed lower threshold
The power rail (4.5V, 10V or 18V) has gone lower than the allowed lower threshold
DCDC and DCAC may be limited or unavailable.
No
DC side of DCAC converter B (DCACB) temperature is too high
DCACB DC temperature exceeds the allowed temperature threshold
DCAC may be limited or unavailable.
No
DC side of DCAC converter A (DCACA) temperature is too high
DCACA DC temperature exceeds the allowed temperature threshold
DCAC may be limited or unavailable.
No
The DC link side DCDC converter (DCDCB) resonant tank current goes above the allowed current threshold
The DC link side DCDC converter (DCDCB) resonant tank current goes above the allowed current threshold
DCDC functionality may be limited or paused
No
The low voltage (LV) side of the DC link DCDC converter (DCDCB) temperature is too high
DCDCB LV temperature exceeds the allowed temperature threshold
DCDC functionality may be limited or paused
No
The pack side DCDC converter (DCDCA) resonant tank current goes above the allowed current threshold
The pack side DCDC converter (DCDCA) resonant tank current goes above the allowed current threshold
DCDC functionality may be limited or paused
No
The high voltage (HV) side of the pack side DCDC converter (DCDCA) temperature is too high
DCDCA HV temperature exceeds the allowed temperature threshold
DCDC functionality may be limited or paused
No
The DCAC converter B (DCACB) resonant tank current goes above the allowed current threshold
The DCACB resonant tank current goes above the allowed current threshold
DCAC may be limited or unavailable.
No
The low voltage (LV) side of the pack side DCDC converter (DCDCA) temperature is too high
DCDCA LV temperature exceeds the allowed temperature threshold
DCDC functionality may be limited or paused
No
The high voltage (HV) DC current goes above the allowed current threshold
The HVDC current exceeds the allowed current threshold
DCAC may be limited or unavailable.
No
The AC Neutral current exceeds the allowed current threshold
The Neutral current exceeds the allowed current threshold
DCAC may be limited or unavailable.
No
The AC Line 3 current exceeds the allowed current threshold
The AC Line 3 current exceeds the allowed current threshold
DCAC may be limited or unavailable.
No
The AC Line 2 to Neutral voltage exceeds the allowed voltage threshold
The AC Line 2 to Neutral voltage exceeds the allowed voltage threshold
DCAC may be limited or unavailable.
No
The AC Line 2 current exceeds the allowed current threshold
The AC Line 2 current exceeds the allowed current threshold
DCAC may be limited or unavailable.
No
The AC Line 2 to Neutral voltage exceeds the allowed voltage threshold
The AC Line 2 to Neutral voltage exceeds the allowed voltage threshold
DCAC may be limited or unavailable.
No
The AC Line 1 current exceeds the allowed current threshold
The AC Line 1 current exceeds the allowed current threshold
DCAC may be limited or unavailable.
No