Alerts
Loading...
Signal Name | Description | Condition | Impact |
---|---|---|---|
The low voltage (LV) bus goes above the allowed voltage threshold.
|
The LV bus voltage goes above the allowed voltage threshold
|
DCDC functionality may be limited or paused
|
|
DCAC converter B (DCACB) AC side sensor 2 (AC2) temperature is too high.
|
DCACB AC2 temperature exceeds the allowed temperature threshold
|
DCAC may be limited or unavailable.
|
|
DCAC converter B (DCACB) AC side sensor 1 (AC1) temperature is too high.
|
DCACB AC1 temperature exceeds the allowed temperature threshold
|
DCAC may be limited or unavailable.
|
|
DCAC converter A (DCACA) AC side sensor 2 (AC2) temperature is too high.
|
DCACA AC2 temperature exceeds the allowed temperature threshold
|
DCAC may be limited or unavailable.
|
|
DCAC converter A (DCACA) AC side sensor 1 (AC1) temperature is too high.
|
DCACA AC1 temperature exceeds the allowed temperature threshold
|
DCAC may be limited or unavailable.
|
|
The coolant temperature is too high.
|
Coolant temperature exceeds the allowed temperature threshold
|
DCDC and DCAC may be limited or unavailable.
|
|
The Power Convertsion System (PCS) ambient temperature is too high.
|
Ambient temperature exceeds the allowed temperature threshold
|
DCDC and DCAC may be limited or unavailable.
|
|
The AC connector temperature is too high.
|
AC connector temperature exceeds the allowed temperature threshold
|
DCAC may be limited or unavailable.
|
|
The planar transformer of DCAC converter B (DCACB) temperature is too high.
|
DCACB planar transformer temperature exceeds the allowed temperature threshold
|
DCAC may be limited or unavailable.
|
|
The planar transformer of DCAC converter A (DCACA) temperature is too high.
|
DCACA planar transformer temperature exceeds the allowed temperature threshold
|
DCAC may be limited or unavailable.
|
|
The DCDC ENABLE hard line functionality is disabled.
|
The DCDC ENABLE line functionality is disabled
|
The high voltage battery controller (HVBATT) and vehicle controller (VC) cannot force shutdown DCDC by de-asserting the DCDC ENABLE line
|
|
The generated power rail (4.5V, 10V, or 18V) has gone lower than the allowed lower threshold.
|
The power rail (4.5V, 10V or 18V) has gone lower than the allowed lower threshold
|
DCDC and DCAC may be limited or unavailable.
|
|
DC side of DCAC converter B (DCACB) temperature is too high.
|
DCACB DC temperature exceeds the allowed temperature threshold
|
DCAC may be limited or unavailable.
|
|
DC side of DCAC converter A (DCACA) temperature is too high.
|
DCACA DC temperature exceeds the allowed temperature threshold
|
DCAC may be limited or unavailable.
|
|
The DC link side DCDC converter (DCDCB) resonant tank current goes above the allowed current threshold.
|
The DC link side DCDC converter (DCDCB) resonant tank current goes above the allowed current threshold
|
DCDC functionality may be limited or paused
|
|
The low voltage (LV) side of the DC link DCDC converter (DCDCB) temperature is too high.
|
DCDCB LV temperature exceeds the allowed temperature threshold
|
DCDC functionality may be limited or paused
|
|
The pack side DCDC converter (DCDCA) resonant tank current goes above the allowed current threshold.
|
The pack side DCDC converter (DCDCA) resonant tank current goes above the allowed current threshold
|
DCDC functionality may be limited or paused
|
|
The high voltage (HV) side of the pack side DCDC converter (DCDCA) temperature is too high.
|
DCDCA HV temperature exceeds the allowed temperature threshold
|
DCDC functionality may be limited or paused
|
|
The DCAC converter B (DCACB) resonant tank current goes above the allowed current threshold.
|
The DCACB resonant tank current goes above the allowed current threshold
|
DCAC may be limited or unavailable.
|
|
The low voltage (LV) side of the pack side DCDC converter (DCDCA) temperature is too high.
|
DCDCA LV temperature exceeds the allowed temperature threshold
|
DCDC functionality may be limited or paused
|