Alerts

Alerts

Signal Name Description Condition Impact
The temperature of the thermal model for the DCDC transformer windings becomes too high
The temperature of the thermal model for the DCDC transformer windings rises above its set limit
The maximum DCDC power may be reduced
DCAC converter A (DCACA) is not operational
DCACA has exhausted all of its retries due to various conditions affecting functionality.
DCAC may be limited or unavailable.
DCAC converter B (DCACB) resonant tank has not been fully calibrated
A tank capacitance or inductance measurement for DCACB is not recorded in Non-Volatile Memory (NVM)
DCAC operation allowed with default resonant tank parameters at reduced surge current limit
DCAC converter A (DCACA) resonant tank has not been fully calibrated
A tank capacitance or inductance measurement for DCACA is not recorded in Non-Volatile Memory (NVM)
DCAC operation allowed with default resonant tank parameters at reduced surge current limit
The DC link side DCDC converter (DCDCB) resonant tank has not been fully calibrated
A tank capacitance or inductance measurement for DCDCB is not recorded in Non-Volatile Memory (NVM)
DCDC operation allowed with default resonant tank parameters, but risk of damaging the converter due to hard switching
The pack side DCDC converter (DCDCA) resonant tank has not been fully calibrated
A tank capacitance or inductance measurement for DCDCA is not recorded in Non-Volatile Memory (NVM)
DCDC operation allowed with default resonant tank parameters, but risk of damaging the converter due to hard switching
The Power Conversion System (PCS) does not receive one or more Controller Area Network (CAN) messages from the User Interface (UI)
The PCS does not receive all expected CAN messages from the UI
DCAC may be limited or unavailable.
The Power Conversion System (PCS) does not receive one or more Controller Area Network (CAN) messages from the High Voltage Processor (HVP)
The PCS does not receive all expected CAN messages from high voltage processor
DCAC may be limited or unavailable.
The Power Conversion System (PCS) does not receive one or more Controller Area Network (CAN) messages from the Charge Port (CP)
The PCS does not receive all expected CAN messages from the CP
DCAC may be limited or unavailable.
The Power Conversion System (PCS) does not receive one or more Controller Area Network (CAN) messages from the Battery Management System (BMS)
The PCS does not receive all expected CAN messages from the BMS
DCDC and DCAC may be limited or unavailable.
The Power Conversion System (PCS) detects the DCDC ENABLE digital line is deasserted when DCDC is commanded to operate.
The PCS detects the DCDC ENABLE digital line is deasserted when DCDC is commanded to operate
DCDC converter will be forced shutdown due to this ENABLE line deassertion
The DCAC high voltage (HV) measurement goes below the allowed voltage threshold
The DCAC HV voltage goes below the allowed voltage threshold
DCAC functionality may be limited or paused
The DCAC high voltage (HV) measurement goes above the allowed voltage threshold
The DCAC HV voltage goes above the allowed voltage threshold
DCAC functionality may be limited or paused
The sensor measuring the bottom half of the high voltage (HV) battery voltage detects a value below the allowed voltage threshold
The sensor measuring the bottom half of the HV battery voltage goes below the allowed voltage threshold
DCDC functionality may be limited or paused
The sensor measuring the top half of the high voltage (HV) battery voltage detects a value below the allowed voltage threshold
The sensor measuring the top half of the HV battery voltage goes below the allowed voltage threshold
DCDC functionality may be limited or paused
The high voltage (HV) battery goes below the allowed voltage threshold
The HV battery voltage goes below the allowed voltage threshold
DCDC functionality may be limited or paused
The sensor measuring the bottom half of the high voltage (HV) bus voltage detects a value below the allowed voltage threshold
The sensor measuring the bottom half of the HV bus voltage goes below the allowed voltage threshold
DCDC functionality may be limited or paused
The sensor measuring the top half of the high voltage (HV) bus voltage detects a value below the allowed voltage threshold
The sensor measuring the top half of the HV bus voltage goes below the allowed voltage threshold
DCDC functionality may be limited or paused
The high voltage (HV) bus goes below the allowed voltage threshold
The HV bus voltage goes below the allowed voltage threshold
DCDC functionality may be limited or paused
The high voltage (HV) bus goes above the allowed voltage threshold
The HV bus voltage goes above the allowed voltage threshold
DCDC functionality may be limited or paused