Alerts

Alerts

Signal Name Description Condition Impact
Pedal Monitor Warning: Switch-off Path Test Failed.
This condition is set when the power electronics and DI-PM switch-off path test fails, most likely due to damaged inverter hardware.
The safety monitor will inhibit torque and excess heat production for the remainder of the drive cycle.
Pedal Monitor Warning: Peripheral Register Configuration Error.
This condition is set when a the GPIO register of the ECU reports a configuration error, intended to be a diagnostic alert only.
No immediate impact.
Pedal Monitor Warning: DI Heartbeat is missing.
The safety monitor sets this condition when DI Heartbeat communication is too fast or too slow.
The safety monitor will initiate a unit limp condition for the remainder of the drive cycle.
Pedal Monitor Warning: Reset for unintended reason.
This condition is set when this ECU powers on and detects an abnormal reset condition from the previous power cycle (for example, from a watchdog timeout).
No immediate impact.
Pedal Monitor Warning: Stator Temperature Sensor Error.
The safety monitor sets this condition when stator temperature sensor measurements are irrational or out of bounds.
No immediate impact.
Pedal Monitor Warning: Motor Encoder error.
The safety monitor sets this condition when encoder speed sensor measurements are irrational or out of bounds.
The safety monitor will initiate a unit limp condition for the remainder of the drive cycle.
Pedal Monitor Warning: Parking Brake CAN node is missing.
The safety monitor sets this condition when CAN communication from Parking Brake CAN node is considered irrational or missing.
Parking Brake CAN node is considered not communicating on CAN for remainder of drive cycle.
Pedal Monitor Warning: CAN hardware error.
This condiiton is set when CAN peripheral hardware indicates an overrun or transmission error on the primary CAN bus.
No immediate impact, may lead to indicating an MIA condition for the specific CAN ID listed in alert payload.
Pedal Monitor Warning: Phase Current Irrational.
The safety monitor sets this condition when phase current sensor measurements are irrational or out of bounds.
The safety monitor will initiate a unit limp condition for the remainder of the drive cycle.
Pedal Monitor Warning: DI CAN node is missing.
The safety monitor sets this condition when CAN communication from DI is considered irrational or missing.
DI is considered not communicating on CAN for remainder of drive cycle.
Pedal Monitor Warning: DI torque actual does not match PM torque measured.
Set when absolute difference between DIx_torqueActual and PMx_torqueMeasured is > 100Nm for 100ms
No immediate impact.
Pedal Monitor Warning: Torque Detected in non-torque producing gear.
The safety monitor sets this condition torque production error is detected.
The safety monitor will inhibit torque and excess heat production for the remainder of the drive cycle.
Pedal Monitor Warning: Deceleration Torque.
The safety monitor sets this condition torque production error is detected.
The safety monitor will inhibit torque and excess heat production for the remainder of the drive cycle.
Pedal Monitor Warning: Torque Reversal.
The safety monitor sets this condition torque production error is detected.
The safety monitor will inhibit torque and excess heat production for the remainder of the drive cycle.
Pedal Monitor Warning: Accumulated Torque.
The safety monitor sets this condition torque production error is detected.
The safety monitor will inhibit torque and excess heat production for the remainder of the drive cycle.
Pedal Monitor Warning: Absolute Torque.
The safety monitor sets this condition torque production error is detected.
The safety monitor will inhibit torque and excess heat production for the remainder of the drive cycle.
Pedal Monitor Warning: Smart watchdog fault.
The safety monitor sets this condition when smart watchdog faults are present.
Loss of torque production. The safety monitor and drive inverter may reset.
Pedal Monitor Warning: Crystal oscillator inactive.
This condition is at application boot when the external crystal is not the active clock source.
Unit may have limited torque or torque disablement with this alert present, see other active alerts for more details.
Pedal Monitor Warning: Torque Intervention.
The safety monitor sets this condition and indicates diagnostic information in its payload for root cause analysis.
The safety monitor will inhibit torque and excess heat production for the remainder of the drive cycle.
Pedal Monitor Warning: ECC Protection anamoly detected.
This condition is set when ECC protection detected a flash fetch or RAM read error, intended to be a diagonstic alert only.
No immediate impact.