Alerts

Alerts

Signal Name Description Condition Impact Important
Occupancy sensor short, switch button monitoring or voltage incompatibility detected.
Alert payload reason is detected
Loss of button monitoring, unparking or other features
No
Dataset EEPROM may be corrupted or incorrect.
Problem with dataset EEPROM memory detected
Loss of all PPB functionality
No
One of the interlocks required for PPB to Unpark is errored or invalid.
One of the interlock sources over CAN is being reported by PPB as error or invalid
Unpark is not allowed
No
PPB's received vehicle speed source fault detected.
One of the speed sources that PPB uses is showing error or invalid
Motion state may not be able to be determined - Used in ARA, EAS
No
High side tractor solenoid short circuit detected.
Hardware issue detected with the high side solenoid relay
Loss of tractor/trailer functionality
No
Low side trailer switch short or open circuit detected - Internal to Hardware.
Hardware issue detected with the trailer low side switch
Loss of trailer functionality
No
Low side tractor switch short or open circuit detected - Internal to Hardware.
Hardware issue detected with the tractor low side switch
Loss of tractor functionality
No
Trailer solenoid release pin/wire short detected.
Short detected on the trailer solenoid release line
Not able to apply and release trailer park brakes
No
Trailer solenoid apply pin/wire short detected.
Short detected on the trailer solenoid apply line
Not able to apply and release trailer park brakes
No
Tractor solenoid release pin/wire short detected.
Short detected on the tractor solenoid release line
Not able to apply and release tractor park brakes
No
Tractor solenoid apply pin/wire short detected.
Short detected on the tractor solenoid apply line
Not able to apply and release tractor park brakes
No
Trailer pressure sensor supply pin/wire short detected.
Short on the trailer pressure sensor supply pin detected
Loss of trailer pressure sensing
No
Tractor pressure sensor supply pin/wire short detected.
Short on the tractor pressure sensor supply pin detected
Loss of tractor pressure sensing
No
The Pneumatic Park Brake (PPB) electronic control unit (ECU) detects a hardware condition on the occupancy sensor, or it does not receive the expected cabin door status from the Left Vehicle Controller (VCLEFT) over the Controller Area Network (CAN).
The PPB ECU does not receive the expected cabin door status from the VCLEFT and/or detects a hardware condition on the occupancy sensor.
The Anti-Rollaway feature may be unavailable.
No
The Pneumatic Park Brake (PPB) electronic control unit (ECU) detects a hardware condition on the occupancy sensor, or it does not receive the expected cabin door status from the Left Vehicle Controller (VCLEFT) over the Controller Area Network (CAN).
The PPB ECU does not receive the expected cabin door status from the VCLEFT and/or detects a hardware condition on the occupancy sensor.
The Anti-Rollaway feature may be unavailable.
No
Auxillary pressure sensor may be shorted.
Auxillary pressure sensor becomes shorted
Loss of auxillary pressure sensor output
No
PCBA may be shorted internally.
Internal PCBA Short on PPB detected
Unable to preform checks on PPB
No
Trailer pressure sensor may be shorted.
Trailer pressure sensor becomes shorted
Loss of ability to read trailer pressure sensor
No
Tractor pressure sensor may be shorted.
Tractor pressure sensor becomes shorted
Loss of ability to read tractor pressure sensor
No
Park Brake LV Battery voltage fault.
Battery voltage is above 17V or below 9V threshold
All park brake features disabled
No