Alerts

Alerts

Signal Name Description Condition Impact Important
The seat has detected that the track motor has exceeded normal operating times
The operating time has exceeded 120 seconds within 5 minutes
The seat track motor will be disabled
No
The bridge gate driver experienced a condition affecting its operation.
The bridge gate driver reports a condition affecting its operation.
Actuators controlled by the bridge gate driver may be inoperative.
No
The seat occupancy switch is faulted
The seat occupancy switch is shorted to GND or 8V rail
Occupancy sensing will be impacted
No
One or more of the expected messages the electronic control unit (ECU) receives periodically from the high voltage processor (HVP) ECU is not received, indicating the HVP may be unavailable (MIA).
One or more of the expected messages from the HVP ECU is not received.
Vehicle may be unable to drive. Charging may be limited or unavailable.
No
OCS empty seat calibration is mismatched with calibration programmed at board manufacturing
OCS empty seat calibration is below 590 of board manufacturing calibration
Occupancy sensing will be impacted
No
OCS both seatback and cushion likely disconnected
OCS Sensor reading tosDeltaCM is less than 140
Occupancy sensing will be impacted
No
OCS has been incorrectly calibrated by the manufacturer
OCS manufacturing calibration is missing or invalid
Occupancy sensing will be impacted
No
OCS Sensor reading is higher than expected
OCS Sensor reading tosDeltaEmpty is greater than 600
Occupancy sensing will be impacted
No
OCS Sensor reading is lower than expected
OCS Sensor reading tosDeltaEmpty is less than -150
Occupancy sensing will be impacted
No
OCS Seatback is likely disconnected
OCS Sensor reading tosDeltaCM is less than 590
Occupancy sensing will be impacted
No
OCS cushion or heat pad has been disconnected
No heat pad current is seen when heater is turned on
Occupancy sensing will be impacted
No
The TOS communication failed
The TOS communication failed
Occupancy sensing will be impacted
No
The Temp Humidity occupancy sensor communication failed
The Temp Humidity occupancy sensor communication failed
Occupancy sensing will be impacted
No
The seat track abuse has been detected, maximum number of events per time exceeded
The maximum number of operating events per time has been exceeded
The seat track motor will be disabled
No
The Cushion occupancy sensor reading does not match other occupancy sensors
Cushion occupancy sensor reading does not match other occupancy sensors
Occupancy sensing will be impacted
No
TOS sensor data not received on startup
Unable to receive valid new data from TOS for at least 3 seconds after startup
Occupancy sensing will be impacted
No
A large voltage drop is detected in the input power to the vehicle controller, indicating the resistance on the input power feed to the vehicle controller is higher than expected.
Estimated resistance on the input power feed to the vehicle controller is higher than expected.
The vehicle controller may be unavailable due to lack of adequate input power, limiting vehicle functionality or making the vehicle inoperable, with at least one other alert specific to that condition present.
No
The Temp Humidity occupancy sensor reads invalid value
Temp Humidity occupancy sensor reading is valid
Occupancy sensing will be impacted
No
The Spare occupancy sensor reads as shorted to ground
Spare occupancy sensor reading is less than x
Occupancy sensing will be impacted
No
The Spare occupancy sensor calibration is missing
The Spare occupancy sensor is not yet calibrated or lost calibration
Occupancy sensing will be impacted
No