| Signal Name | Description | Condition | Impact |
|---|---|---|---|
|
The supply air valve has faulted.
|
An unexpected current was measured on the supply air valve
|
The air suspension system may not work as intended
|
|
|
The mid-left suspension air valve has faulted.
|
An unexpected current was measured on the mid-left suspension air valve
|
The air suspension system may not work as intended
|
|
|
The mid-right suspension air valve has faulted.
|
An unexpected current was measured on the mid-right suspension air valve
|
The air suspension system may not work as intended
|
|
|
The valve block pressure sensor output voltage is too high.
|
A voltage above the maximum was read on the pressure sensor
|
The air suspension system may not work as intended
|
|
|
The air exhaust valve has shorted.
|
A short was detected on the air exhaust valve
|
The air suspension system may not work as intended
|
|
|
The air exhaust valve is disconnected.
|
An open circuit was detected on the air exhaust valve
|
The air suspension system may not work as intended
|
|
|
The valve block input voltage does not fall within a normal range.
|
An abnormal voltage was read on the valve block
|
The air suspension system may not work as intended
|
|
|
The front suspension air valve has faulted.
|
An unexpected current was measured on the front suspension air valve
|
The air suspension system may not work as intended
|
|
|
The thermal system is currently being filled while the vehicle is in drive.
|
The refrigerant fluid fill/drain routine is run
|
Powertrain and HVAC performance will be limited
|
|
|
The front air suspension valve has shorted.
|
A short on the front air suspension valve was detected
|
The air suspension system may not work as intended
|
|
|
The sleeper duct temperature sensor has an electrical fault.
|
The sensor is disconnected or short-circuited to ground
|
HVAC performance may be limited
|
|
|
The panel duct temperature sensor has an electrical fault.
|
The sensor is disconnected or short-circuited to ground
|
HVAC performance may be limited
|
|
|
The bulk duct temperature sensor has an electrical fault.
|
The sensor is disconnected or short-circuited to ground
|
HVAC performance may be limited
|
|
|
The mid-right air suspension valve is disconnected.
|
An open circuit was detected on the mid-right air suspension valve
|
The air suspension system may not work as intended
|
|
|
The refrigerant system will not operate (No A/C and no chiller) when the vehicle is not factory gated and the refrigerant system has not been filled.
|
The vehicle is not factory gated and the refrigerant is not filled or the fill/drain routine is active.
|
Powertrain and HVAC performance will be limited, as the compressor will be disabled and the refrigerant valves (solenoid/EXV) will be opened.
|
|
|
The chiller EXV's motor driver has reported a fault.
|
The EXV motor driver has reported a fault.
|
Cabin / powertrain cooling and heating performance may be limited.
|
|
|
The liquid cooled condenser inlet solenoid has encountered an electrical fault (short, disconnect or internal).
|
The liquid cooled condenser inlet solenoid is consuming less than 0.2 Amps, or greater than 2.0 Amps, when active
|
HVAC cabin, cooling and heating, and powertrain performance may be limited.
|
|
|
The Thermal Fan has encountered an electrical fault (short, disconnect or internal).
|
The Thermal Fan is faulted or consuming less than 10 Amps when above 2000 RPM
|
HVAC cabin, cooling and heating, and powertrain performance may be limited.
|
|
|
The chiller EXV's motor driver has reported a fault.
|
The EXV motor driver has reported a fault.
|
Cabin / powertrain cooling and heating performance may be limited.
|
|
|
The air supply valve has shorted.
|
A short was detected on the air supply valve
|
The air suspension system may not work as intended
|