Signal Name Description Condition Impact
The supply air valve has faulted.
An unexpected current was measured on the supply air valve
The air suspension system may not work as intended
The mid-left suspension air valve has faulted.
An unexpected current was measured on the mid-left suspension air valve
The air suspension system may not work as intended
The mid-right suspension air valve has faulted.
An unexpected current was measured on the mid-right suspension air valve
The air suspension system may not work as intended
The valve block pressure sensor output voltage is too high.
A voltage above the maximum was read on the pressure sensor
The air suspension system may not work as intended
The air exhaust valve has shorted.
A short was detected on the air exhaust valve
The air suspension system may not work as intended
The air exhaust valve is disconnected.
An open circuit was detected on the air exhaust valve
The air suspension system may not work as intended
The valve block input voltage does not fall within a normal range.
An abnormal voltage was read on the valve block
The air suspension system may not work as intended
The front suspension air valve has faulted.
An unexpected current was measured on the front suspension air valve
The air suspension system may not work as intended
The thermal system is currently being filled while the vehicle is in drive.
The refrigerant fluid fill/drain routine is run
Powertrain and HVAC performance will be limited
The front air suspension valve has shorted.
A short on the front air suspension valve was detected
The air suspension system may not work as intended
The sleeper duct temperature sensor has an electrical fault.
The sensor is disconnected or short-circuited to ground
HVAC performance may be limited
The panel duct temperature sensor has an electrical fault.
The sensor is disconnected or short-circuited to ground
HVAC performance may be limited
The bulk duct temperature sensor has an electrical fault.
The sensor is disconnected or short-circuited to ground
HVAC performance may be limited
The mid-right air suspension valve is disconnected.
An open circuit was detected on the mid-right air suspension valve
The air suspension system may not work as intended
The refrigerant system will not operate (No A/C and no chiller) when the vehicle is not factory gated and the refrigerant system has not been filled.
The vehicle is not factory gated and the refrigerant is not filled or the fill/drain routine is active.
Powertrain and HVAC performance will be limited, as the compressor will be disabled and the refrigerant valves (solenoid/EXV) will be opened.
The chiller EXV's motor driver has reported a fault.
The EXV motor driver has reported a fault.
Cabin / powertrain cooling and heating performance may be limited.
The liquid cooled condenser inlet solenoid has encountered an electrical fault (short, disconnect or internal).
The liquid cooled condenser inlet solenoid is consuming less than 0.2 Amps, or greater than 2.0 Amps, when active
HVAC cabin, cooling and heating, and powertrain performance may be limited.
The Thermal Fan has encountered an electrical fault (short, disconnect or internal).
The Thermal Fan is faulted or consuming less than 10 Amps when above 2000 RPM
HVAC cabin, cooling and heating, and powertrain performance may be limited.
The chiller EXV's motor driver has reported a fault.
The EXV motor driver has reported a fault.
Cabin / powertrain cooling and heating performance may be limited.
The air supply valve has shorted.
A short was detected on the air supply valve
The air suspension system may not work as intended