Signal Name Description Condition Impact
Not Available
Vehicle did not unlock after crash.
These are the repercussions of the alert being set
Provides information about the unexpected stop.
PLG stops unexpectedly
-
Not Available
No falcon door pinch strips pressed or disconnected
Pressed: door will not move unless under manual control, Disconnected: TBD
Not Available
A falcon door (B Pillar Button) button is stuck down
Falcon door B pillar button that is stuck, it's signal is ignored
Not Available
Falcon door 12V pump rail in error
Falcon door will not move or performance will be impacted
Not Available
Falcon 5V rail in error
Falcon door position sensors and pinch strips will not function
Check spoiler mechanism. mechanical failure may be present.
Spoiler motor stall current is reached when the spoiler in not near either endstop
Spoiler may have mechanical issue or be blocked
Production vehicle should not have Debug Jumper in place. Remove jumper from ECU.
ECU Debug Jumper is set.
ECU Debug Jumper will disable SBC watchdog, preventing external watchdog reset protection.
Log contains CPU load for each task.
CPU load exceeds 80%.
High CPU load can indicate ineffecient code.
Log contains stack usage for each task.
Stack usage exceeds 80% for any task.
Stack overflow can occur if there is not enough stack space.
Check spoiler mechanism. mechanical failure may be present.
Spoiler motor stalls during auto calibration state
Spoiler may have mechanical issue or be blocked
Not Available
The Freescale HSD has been returned bad data on the MISO line from the microprocessor more than 10 times in a row.
HSD outputs could toggle endlessly causing lights to strobe forever.
reseting the controller should fix the issue
Driver side config stored in NVRAM does not match the config sent by GTW
controller may have behaviors that correspond with the wrong side of the car
Communication failure to the oil pump
The oil pump has experienced a communication or connection fault, detected by the rear body controller.
Oil pump will operate at max flow rate if LIN failure and no flow if unpowered.
Not Available
setcondition
These are the repercussions of the alert being set
Not Available
setcondition
These are the repercussions of the alert being set
Not Available
setcondition
These are the repercussions of the alert being set
Not Available
setcondition
These are the repercussions of the alert being set
Not Available
setcondition
These are the repercussions of the alert being set
Not Available
setcondition
These are the repercussions of the alert being set