Alerts

Alerts

Signal Name Description Condition Impact
DAS_w014_swAssert
-
DAS_w013_Cam_Watchdog
-
DAS_w012_Cam_BootFailure
-
DAS_w011_scaEvent
-
DAS_w010_radcCalibIssue
-
DAS_w009_aebFault
-
DAS_w006_aebCancelled
-
DAS_w005_fcwCancelled
-
DAS_w004_accDisabled
-
The vehicle controller detects that precharging the high voltage (HV) DC bus may be unsuccessful, which may lead to the inability to close the HV contactors and a complete loss of vehicle power. Charging vehicles with GB (charging standard used in China) charge ports requires opening and closing the HV contactors.
The vehicle controller detects that precharging the HV DC bus may be unsuccessful.
If GB DC charging is attempted, the charge session may fail, the HV contactors may not close again, and there may be a complete loss of LV power.
The charge port inlet pin temperature has reached an unacceptable level (greatly exceeds normal operating range), causing AC charging to stop.
The charge port inlet pin temperature reaches a level where it is unacceptable to continue AC charging (temperature detected greatly exceeds normal operating range).
AC charging will be interrupted and remain unavailable until a charge cable cycle occurs (disconnect and reconnect) and the charge port inlet pin temperature returns to normal operating range.
The charge port inlet pin temperature has reached a level where limiting AC charge current is necessary until temperature returns to normal operating range.
The charge port inlet pin temperature reaches an unexpected level (temperature detected exceeds normal operating range).
AC charge current is limited.
The Combined Charging System (CCS) charge station reports that it has experienced an unrecoverable error. Charging may not start or may be interrupted, with a charge cable cycle (disconnect, then reconnect to vehicle) required before charging can start or resume.
The Combined Charging System (CCS) charge station sends a message indicating it has experienced an unrecoverable error.
Charging may not start or may be unexpectedly interrupted. A charge cable cycle (disconnect, then reconnect to vehicle) is required before charging can start or resume.
The Power Line Communication (PLC) modem application for the Charge Port (CP) electronic control unit (ECU) does not load after a maximum number of automatic retries. DC fast charging will be unavailable at Combined Charging System (CCS) charge stations.
The Power Line Communication (PLC) modem application does not load after multiple consecutive attempts / maximum number of retries.
DC fast charging will be unavailable at Combined Charging System (CCS) charge stations.
The charge port detected an unsupported charging adapter.
An unsupported charging adapter was detected
Charging will not begin with the unsupported adapter
A GB (Charging standard used in China) DC Supercharger reports an issue with the connector.
The GB DC Supercharger reports via the communication channel that it has detected an issue with the connector.
GB DC charging does not start or is interrupted.
A CHAdeMO adapter communicating over single wire controller area network (SWCAN) reports that it has encountered an issue.
The CHAdeMO adapter reports via SWCAN that it has entered the faulted state.
Charging does not start or is interrupted.
A Supercharger post communicating over single wire controller area network (SWCAN) reports that it has encountered an issue.
The Supercharger reports via SWCAN that it has entered the faulted state.
Charging does not start or is interrupted.
DAS_w030_Heater_Issue
-
DAS_w027_ECU_Reset_Fault
-