Alerts

Alerts

Signal Name Description Condition Impact Important
PARK3_w001_s1_internalFail
-
No
The 1st Row (Front) Passenger Occupancy Classification System (OCS1P) detects the 1st row seat is not compatible with the reported vehicle region.
The OCS1P detects a seat that is not compatible with the reported vehicle region.
The occupancy classification cannot be performed.
No
The 1st Row (Front) Passenger Occupancy Classification System (OCS1P) detects a passenger airbag that is not compatible with the installed OCS1P sensor.
The OCS1P detects a passenger airbag that is not compatible with the installed OCS1P sensor.
The occupancy classification cannot be performed.
No
The sandwich sensor has a discrepancy in its calibration
The calibration values saved in flash are invalid
The classification cannot be performed
No
The seatback self capacitance sensor is not calibrated
The calibration value saved in flash is invalid
The classification cannot be performed
No
The cushion self capacitance sensor is not calibrated
The calibration value saved in flash is invalid
The classification cannot be performed
No
The sandwich sensor is not calibrated
The calibration value saved in flash is invalid
The classification cannot be performed
No
The seatback self capacitance sensor is shorted to ground
The frequency reading is < 1kHz
The classification cannot be performed
No
The seatback self capacitance sensor is low
The frequency reading is < 25kHz but > 1kHz
The classification cannot be performed
No
The seatback self capacitance sensor is open
The frequency reading is > 45kHz
The classification cannot be performed
No
The cushion self capacitance sensor is shorted to ground
The frequency reading is < 1kHz
The classification cannot be performed
No
The cushion self capacitance sensor is low
The frequency reading is < 25kHz but > 1kHz
The classification cannot be performed
No
The cushion self capacitance sensor is open
The frequency reading is > 45kHz
The classification cannot be performed
No
The sandwich sensor is shorted to ground
The frequency reading is < 1kHz
The classification cannot be performed
No
The sandwich sensor is low
The frequency reading is < 22kHz but > 1kHz
The classification cannot be performed
No
Alert indicating a UI process has exited with an error, payload contains the exited process name and exit signal.
UI process exits with error.
A process stopped unexpectedly. Depending on the specific process, some features may be unavailable.
No
The display manager detects an error with the Field Programmable Gate Array (FPGA) dedicated to the rear view camera.
The display manager detects an error with the FPGA for the rear view camera.
The rear view camera may be unavailable or not operate as expected.
No
A phone contact sync with more than 5000 contacts completed. Alert payload contains the number of contacts loaded.
This alert is set when a phone is connected to Bluetooth and a phone contact is synced with over five thousand contacts.
Bluetooth connection and call quality may be impacted during a large phone contact sync. Normal operation is expected after the sync is completed.
No
An error with a User Interface (UI) database was detected and the automatic recovery was not able to restore its functionality. Therefore some data from this database may be missing or incorrect and dependent features may not function as expected.
Database corruption recovery mechanism fails, triggers on each failed automatic recovery attempt.
Impacts specific UI features dependent on the affected database.
No
The User Interface (UI) Electronic Control Unit (ECU) detects one or both of the cellular antenna is experiencing a connection condition.
The cellular antenna load measurements are outside normal bounds.
The cellular connection signal reception and data throughput may be reduced.
No