Signal Name | Description | Condition | Impact |
---|---|---|---|
Secondary disconnect controller (SDC) phase voltage sensors are providing irrational values.
|
At least one phase voltage measurement remains low while voltage should be constantly switching between low and high.
|
Pyro disconnect may not function as expected.
|
|
Secondary disconnect controller (SDC) HV bus voltage sensor is providing irrational values.
|
HV bus voltage measurement is low while HV backup rail is up.
|
Pyro disconnect may not function as expected.
|
|
Secondary disconnect controller (SDC) HV backup rail voltage sensor is providing irrational values.
|
HV backup rail voltage measured low while Power Good (PGOOD) hardware signal to SDC is asserted.
|
Pyro disconnect may not function as expected.
|
|
Secondary disconnect controller (SDC) boost rail voltage sensor is providing irrational values.
|
SDC boost rail sensor reading is below operational value while HV backup rail voltage measurement (Vbackup) is at nominal value.
|
Pyro disconnect may not function as expected.
|
|
One of the phase current sensors is reading an irrational out-of-range value.
|
One of the phase current sensors is reading an irrational out-of-range value.
|
The Secondary Disconnect Controller (SDC) will be disabled.
|
|
At least one phase current sensor offset is outside of the expected limits.
|
Phase current sensor offset is higher or lower than expected limit.
|
Pyro disconnect may not function as expected.
|
|
Secondary disconnect controller (SDC) reference voltage (Vref) for current sensor measurement is irrational, making SDC unable to monitor drive unit electrical state.
|
SDC reference voltage (Vref) measurement is outside of expected range.
|
Pyro disconnect may not function as expected.
|
|
Universal asynchronous receiver-transmitter (UART) data version differs between drive inverter (DI) and secondary disconnect controller (SDC).
|
UART data version detected as differing between DI and SDC.
|
Unable to run pyro self-test.
|
|
HVLINK messages are not being received by secondary disconnect controller (SDC).
|
At least one message from HVLINK consumed by SDC is not received.
|
Active discharge control by SDC may be forced ON.
|
|
Secondary disconnect controller (SDC) detected abnormal motor currents.
|
Detection of abnormal drive unit currents by the SDC when drive inverter (DI) is not switching.
|
SDC may trigger the pyro disconnect.
|
|
Secondary disconnect controller (SDC) triggered the 2-phase disconnect mechanism.
|
SDC detects abnormal electrical condition.
|
Drive unit may be permanently disabled after 2-phase disconnect occurs.
|
|
Secondary disconnect controller (SDC) motor speed estimate is irrational.
|
SDC estimated motor speed is too high or too low
|
Some SDC functions may be unavailable
|
|
Drive inverter (DI) running-feedback (fdbk) pin to secondary disconnect controller (SDC) is in an irrational state.
|
DI UART data is active, but running-feedback pin state is low.
|
SDC will not skip pyro self-test (PST) if DI is MIA at startup. Potential overlapping pyro self-tests.
|
|
Secondary disconnect controller (SDC) failed the drive unit pyro self-test.
|
Pyro test voltages were out of range during pyro self-test.
|
Pyro disconnect may not function as expected.
|
|
One of the phase current sensors is reading an irrational out-of-range value.
|
One of the phase current sensors is reading an irrational out-of-range value.
|
The Secondary Disconnect Controller (SDC) will be disabled.
|
|
Drive Inverter (DI) controller area network (CAN) or UART communication to the secondary disconnect controller (SDC) is missing (MIA).
|
SDC is not receiving all expected CAN or UART frames from DI.
|
SDC is unable to determine DI status
|
|
Vehicle Controller (VC) LV Power State controller area network (CAN) communication to the secondary disconnect controller (SDC) is missing (MIA).
|
SDC is not receiving all expected CAN frames from VC.
|
SDC is unable to determine if drive inverter (DI) is expected to be LV powered
|
|
Drive inverter (DI) switching-feedback (fdbk) pin to secondary disconnect controller (SDC) is in an irrational state.
|
DI switching-feedback pin is set but DI running-feedback is cleared.
|
Pyro disconnect may not function as expected.
|
|
At least one message the Secondary Disconnect Controller (SDC) expects to receive from the vehicle gateway (GTW) is not received.
|
At least one message from the GTW consumed by the SDC is not received.
|
Timestamp for any ECULOG capturing internal SDC data will be inaccurate, which may complicate diagnosis.
|
|
Secondary disconnect controller (SDC) bus bar temperature sensors providing irrational values.
|
At least one SDC bus bar temperature sensor value is outside expected range.
|
At least one bus bar temperature is unavailable, which may affect pyro disconnect functionality.
|