Alerts

Alerts

Signal Name Description Condition Impact
Drive Inverter (DI) controller area network (CAN) or UART communication to the secondary disconnect controller (SDC) is missing (MIA).
SDC is not receiving all expected CAN or UART frames from DI.
SDC is unable to determine DI status
Vehicle Controller (VC) LV Power State controller area network (CAN) communication to the secondary disconnect controller (SDC) is missing (MIA).
SDC is not receiving all expected CAN frames from VC.
SDC is unable to determine if drive inverter (DI) is expected to be LV powered
SEC_w004_remoteAccessRejected
-
SEC_w003_key3BatteryLow
-
SEC_w002_key2BatteryLow
-
SEC_w001_key1BatteryLow
-
One of the phase current sensors is reading an irrational out-of-range value.
One of the phase current sensors is reading an irrational out-of-range value.
The Secondary Disconnect Controller (SDC) will be disabled.
Drive Inverter (DI) controller area network (CAN) or UART communication to the secondary disconnect controller (SDC) is missing (MIA).
SDC is not receiving all expected CAN or UART frames from DI.
SDC is unable to determine DI status
Vehicle Controller (VC) LV Power State controller area network (CAN) communication to the secondary disconnect controller (SDC) is missing (MIA).
SDC is not receiving all expected CAN frames from VC.
SDC is unable to determine if drive inverter (DI) is expected to be LV powered
Drive inverter (DI) switching-feedback (fdbk) pin to secondary disconnect controller (SDC) is in an irrational state.
DI switching-feedback pin is set but DI running-feedback is cleared.
Pyro disconnect may not function as expected.
At least one message the Secondary Disconnect Controller (SDC) expects to receive from the vehicle gateway (GTW) is not received.
At least one message from the GTW consumed by the SDC is not received.
Timestamp for any ECULOG capturing internal SDC data will be inaccurate, which may complicate diagnosis.
Drive inverter (DI) switching-feedback (fdbk) pin to secondary disconnect controller (SDC) is in an irrational state.
DI switching-feedback pin is set but DI running-feedback is cleared.
Pyro disconnect may not function as expected.
Secondary disconnect controller (SDC) bus bar temperature sensors providing irrational values.
At least one SDC bus bar temperature sensor value is outside expected range.
At least one bus bar temperature is unavailable, which may affect pyro disconnect functionality.
The external electrically erasable programmable read-only memory (EEPROM) is returning unexpected data over the serial peripheral interface (SPI).
Invalid data received from external EEPROM over SPI.
Analysis of trigger condition for a previous pyro disconnect event cannot be completed because EEPROM data is inaccessible.
Secondary disconnect controller (SDC) detected abnormal electrical currents during a previous power-ON state. Data retrieved from electrically erasable programmable read-only memory (EEPROM).
SDC detected abnormal electrical currents when drive inverter (DI) was not switching as expected during a previous power cycle.
Drive unit may not be functional due to previous electrical issue.
Secondary disconnect controller (SDC) triggered the 2-phase disconnect mechanism during a previous power ON state. Alert log signal data retrieved from electrically erasable programmable read-only memory (EEPROM) to be used for pyro disconnect trigger investigation afterward.
SDC reads alert log signal data from EEPROM for a previous pyro disconnect event.
Drive unit may not be functional due to previous pyro disconnect.
The external analog to digital converter (ADC) is returning invalid data over the serial peripheral interface (SPI).
Invalid data is received from the external ADC over SPI.
Phase voltage sensing data is incorrect, which may affect pyro disconnect functionality.
Secondary disconnect controller (SDC) phase voltage sensors are providing irrational values.
At least one phase voltage measurement remains low while voltage should be constantly switching between low and high.
Pyro disconnect may not function as expected.
Secondary disconnect controller (SDC) HV bus voltage sensor is providing irrational values.
HV bus voltage measurement is low while HV backup rail is up.
Pyro disconnect may not function as expected.
Secondary disconnect controller (SDC) HV backup rail voltage sensor is providing irrational values.
HV backup rail voltage measured low while Power Good (PGOOD) hardware signal to SDC is asserted.
Pyro disconnect may not function as expected.