Alerts
Loading...
Signal Name | Description | Condition | Impact |
---|---|---|---|
Drive Inverter (DI) controller area network (CAN) or UART communication to the secondary disconnect controller (SDC) is missing (MIA).
|
SDC is not receiving all expected CAN or UART frames from DI.
|
SDC is unable to determine DI status
|
|
Vehicle Controller (VC) LV Power State controller area network (CAN) communication to the secondary disconnect controller (SDC) is missing (MIA).
|
SDC is not receiving all expected CAN frames from VC.
|
SDC is unable to determine if drive inverter (DI) is expected to be LV powered
|
|
SEC_w004_remoteAccessRejected
|
|
-
|
|
SEC_w003_key3BatteryLow
|
|
-
|
|
SEC_w002_key2BatteryLow
|
|
-
|
|
SEC_w001_key1BatteryLow
|
|
-
|
|
One of the phase current sensors is reading an irrational out-of-range value.
|
One of the phase current sensors is reading an irrational out-of-range value.
|
The Secondary Disconnect Controller (SDC) will be disabled.
|
|
Drive Inverter (DI) controller area network (CAN) or UART communication to the secondary disconnect controller (SDC) is missing (MIA).
|
SDC is not receiving all expected CAN or UART frames from DI.
|
SDC is unable to determine DI status
|
|
Vehicle Controller (VC) LV Power State controller area network (CAN) communication to the secondary disconnect controller (SDC) is missing (MIA).
|
SDC is not receiving all expected CAN frames from VC.
|
SDC is unable to determine if drive inverter (DI) is expected to be LV powered
|
|
Drive inverter (DI) switching-feedback (fdbk) pin to secondary disconnect controller (SDC) is in an irrational state.
|
DI switching-feedback pin is set but DI running-feedback is cleared.
|
Pyro disconnect may not function as expected.
|
|
At least one message the Secondary Disconnect Controller (SDC) expects to receive from the vehicle gateway (GTW) is not received.
|
At least one message from the GTW consumed by the SDC is not received.
|
Timestamp for any ECULOG capturing internal SDC data will be inaccurate, which may complicate diagnosis.
|
|
Drive inverter (DI) switching-feedback (fdbk) pin to secondary disconnect controller (SDC) is in an irrational state.
|
DI switching-feedback pin is set but DI running-feedback is cleared.
|
Pyro disconnect may not function as expected.
|
|
Secondary disconnect controller (SDC) bus bar temperature sensors providing irrational values.
|
At least one SDC bus bar temperature sensor value is outside expected range.
|
At least one bus bar temperature is unavailable, which may affect pyro disconnect functionality.
|
|
The external electrically erasable programmable read-only memory (EEPROM) is returning unexpected data over the serial peripheral interface (SPI).
|
Invalid data received from external EEPROM over SPI.
|
Analysis of trigger condition for a previous pyro disconnect event cannot be completed because EEPROM data is inaccessible.
|
|
Secondary disconnect controller (SDC) detected abnormal electrical currents during a previous power-ON state. Data retrieved from electrically erasable programmable read-only memory (EEPROM).
|
SDC detected abnormal electrical currents when drive inverter (DI) was not switching as expected during a previous power cycle.
|
Drive unit may not be functional due to previous electrical issue.
|
|
Secondary disconnect controller (SDC) triggered the 2-phase disconnect mechanism during a previous power ON state. Alert log signal data retrieved from electrically erasable programmable read-only memory (EEPROM) to be used for pyro disconnect trigger investigation afterward.
|
SDC reads alert log signal data from EEPROM for a previous pyro disconnect event.
|
Drive unit may not be functional due to previous pyro disconnect.
|
|
The external analog to digital converter (ADC) is returning invalid data over the serial peripheral interface (SPI).
|
Invalid data is received from the external ADC over SPI.
|
Phase voltage sensing data is incorrect, which may affect pyro disconnect functionality.
|
|
Secondary disconnect controller (SDC) phase voltage sensors are providing irrational values.
|
At least one phase voltage measurement remains low while voltage should be constantly switching between low and high.
|
Pyro disconnect may not function as expected.
|
|
Secondary disconnect controller (SDC) HV bus voltage sensor is providing irrational values.
|
HV bus voltage measurement is low while HV backup rail is up.
|
Pyro disconnect may not function as expected.
|
|
Secondary disconnect controller (SDC) HV backup rail voltage sensor is providing irrational values.
|
HV backup rail voltage measured low while Power Good (PGOOD) hardware signal to SDC is asserted.
|
Pyro disconnect may not function as expected.
|