Alerts

Alerts

Signal Name Description Condition Impact
The device junction temperature sensor reading exceeds the expected temperature threshold.
The device junction temperature sensor reading exceeds the expected temperature threshold.
STITCH will throw warning.
STITCH has been locked out due to an environmental or hardware condition preventing normal operation.
STITCH encounters a hardware or environmental condition preventing normal operation.
STITCH will be persistently locked out.
The STITCH Low Voltage (LV) temperature sensor has detected the internal over temperature threshold exceeds 25.0 degC.
The STITCH LV temperature sensor has detected the internal over temperature threshold exceeds 25.0 degC.
This alert has no functional impact on the vehicle.
Low Voltage (LV) bus voltage precharge timed out. LV rail cannot be brought up.
LV bus voltage precharge times out.
Precharge can enable at too high of a load or short on LV.
A stage 2 instantaneous hardware trip has been detected due to a stage B tank current condition.-.
The absolute tank current has exceeded the expected threshold.
The condition can lead to potential hardware damage if persistently observed.
A stage 1 instantaneous hardware trip has been detected due to a Stage A tank current condition.
The absolute tank current has exceeded the expected threshold.
The condition can lead to potential hardware damage if persistently observed.
The hardware comparator for measurement tank zero-current crossing has experienced a potential failure.
Tank zero-current cross is invalid for 1 second.
STITCH will halt operation, low voltage will not be supported.
The Sigma Delta Filter Module (SDFM) peripheral is not powered, potentially due to not enough DC voltage being provided to the SDFM.
One of the SDFM modules indicates either a clock failure or an irrational reading.
STITCH will halt operation, low voltage will not be supported.
A software trip has been detected due to the stage 2 high voltage side board temperature sensor exceeding the expected temperature limit.
Stage 2 HV temperature sensor reads above the expected threshold.
STITCH will halt operation, low voltage will not be supported.
A software trip has been detected due to the stage 1 high voltage side board temperature sensor exceeding the expected temperature limit.
Stage 1 HV temperature sensor reads above the expected threshold.
STITCH will halt operation, low voltage will not be supported.
A software trip has been detected due to the stage 2 low voltage side board temperature sensor exceeding the expected temperature limit.
Stage 2 LV temperature sensor reads above the expected threshold.
STITCH will halt operation, low voltage will not be supported.
A software trip has been detected due to the stage 1 Low Voltage (LV) side board temperature sensor exceeding the expected temperature limit.
Stage 1 LV temperature sensor reads above the expected threshold.
STITCH will halt operation, low voltage will not be supported.
A fast firmware trip has been detected due to High Voltage (HV) readings exceeding the expected bus top half voltage limit.
Single HV top half bus voltage exceeds the expected threshold.
STITCH will halt operation, low voltage will not be supported.
A software trip has been detected due to High Voltage (HV) readings dropping below the expected undervoltage limit.
HV voltage drops below the expected undervoltage threshold.
STITCH will halt operation, low voltage will not be supported.
A software trip has been detected due to High Voltage (HV) readings exceeding the expected voltage limit.
HV voltage exceeds the expected threshold.
STITCH will halt operation, low voltage will not be supported.
A software trip has been detected due to the stage 2 high voltage side board temperature sensor exceeding the expected temperature limit.
Stage 2 HV temperature sensor reads above the expected threshold.
STITCH will halt operation, low voltage will not be supported.
An instantaneous hardware Low Voltage (LV) trip has been detected due to an overvoltage condition.
LV output voltage exceeds the expected overvoltage threshold.
STITCH will halt operation, low voltage will not be supported.
A stage 1 instantaneous hardware trip has been detected due to a Stage A tank current condition.
The absolute tank current has exceeded the expected threshold.
The condition can lead to potential hardware damage if persistently observed.
A stage 2 instantaneous hardware trip has been detected due to a stage B tank current condition.-.
The absolute tank current has exceeded the expected threshold.
The condition can lead to potential hardware damage if persistently observed.
Low Voltage (LV) bus voltage precharge timed out. LV rail cannot be brought up.
LV bus voltage precharge times out.
Precharge can enable at too high of a load or short on LV.