Alerts
Loading...
| Signal Name | Description | Condition | Impact | Important |
|---|---|---|---|---|
|
A software trip has been detected due to High Voltage (HV) bus top half voltage readings exceeding the expected limit during operation.
|
Single HV top half bus voltage exceeds the expected threshold.
|
STITCH will halt operation, high voltage will not be supported.
|
No
|
|
|
A software trip has been detected due to High Voltage (HV) bus bottom half voltage readings exceeding the expected limit during operation.
|
Single HV bottom half bus voltage exceeds the expected threshold.
|
STITCH will halt operation, high voltage will not be supported.
|
No
|
|
|
STITCH command Controller Area Network (CAN) messages are not received .
|
STITCH command CAN messages are Missing In Action (MIA).
|
STITCH will halt operation, low voltage will not be supported.
|
No
|
|
|
An operation on the Electrically Erasable Programmable Read-Only Memory (EEPROM) has failed. This alert provides record ID, error type, and number of errors since the last task loop.
|
An operation on the EEPROM failed.
|
The payload signals for this alert will indicate the nature of the error.
|
No
|
|
|
An instantaneous hardware Low Voltage (LV) trip has been detected due to an undervoltage condition.
|
LV output voltage drops below the expected undervoltage threshold.
|
STITCH will halt operation, low voltage will not be supported.
|
No
|
|
|
A slow software trip has been detected due to Low Voltage (LV) readings being below the expected threshold during operation.
|
LV output voltage drops below the expected undervoltage threshold for the given time interval.
|
Continuous operation at a low LV output could cause hardware damage.
|
No
|
|
|
A fast firmware trip has been detected due to High Voltage (HV) readings being below the expected bus top half voltage threshold.
|
Single HV top half bus voltage drops below the expected threshold.
|
STITCH will halt operation, low voltage will not be supported.
|
No
|
|
|
A fast firmware trip has been detected due to High Voltage (HV) readings being below the expected bus bottom half voltage threshold.
|
Single HV bottom half bus voltage drops below the expected threshold.
|
STITCH will halt operation, low voltage will not be supported.
|
No
|
|
|
A software trip has been detected due to High Voltage (HV) readings being below the expected bus top half voltage threshold.
|
Single HV top half bus voltage drops below the expected threshold.
|
STITCH will halt operation, low voltage will not be supported.
|
No
|
|
|
A software trip has been detected due to High Voltage (HV) readings being below the expected bus bottom half voltage threshold.
|
Single HV bottom half bus voltage drops below the expected threshold.
|
STITCH will halt operation, low voltage will not be supported.
|
No
|
|
|
A software trip has been detected due to High Voltage (HV) readings exceeding the expected unbalance half voltage threshold.
|
HV half bus voltage unbalance readings exceed the expected threshold for the given time interval.
|
STITCH will halt operation since high HV half bus unbalance would cause device failure.
|
No
|
|
|
A software trip has been detected due to High Voltage (HV) readings exceeding the expected unbalance half voltage threshold during balancer operation.
|
HV half bus voltage unbalance readings exceed the expected threshold for the given time interval.
|
STITCH will throw warning without halting operation.
|
No
|
|
|
A stage 1 controller trip error has been detected due to prolonged Zone Controller (ZC) to Low Voltage (LV) controller saturation.
|
ZC to LV controller output exceeds the expected saturation time interval.
|
STITCH will halt operation due to ZC to LV controller saturation.
|
No
|
|
|
A stage 1 controller trip error has been detected due to prolonged High Voltage (HV) to Zone Controller (ZC) saturation.
|
HV to ZC controller output exceeds the expected saturation time interval.
|
STITCH will halt operation due to HV to ZC controller fail.
|
No
|
|
|
The ambient temperature sensor reading exceeds the expected temperature threshold.
|
The ambient temperature sensor reading exceeds the expected temperature threshold.
|
STITCH will throw warning.
|
No
|
|
|
A fast firmware trip has been detected due to High Voltage (HV) readings exceeding the expected bus top half voltage limit.
|
Single HV top half bus voltage exceeds the expected threshold.
|
STITCH will halt operation, low voltage will not be supported.
|
No
|
|
|
A software trip has been detected due to High Voltage (HV) readings dropping below the expected undervoltage limit.
|
HV voltage drops below the expected undervoltage threshold.
|
STITCH will halt operation, low voltage will not be supported.
|
No
|
|
|
Low Voltage (LV) bus voltage precharge timed out. LV rail cannot be brought up.
|
LV bus voltage precharge times out.
|
Precharge can enable at too high of a load or short on LV.
|
No
|
|
|
An instantaneous hardware Low Voltage (LV) trip has been detected due to an overvoltage condition.
|
LV output voltage exceeds the expected overcurrent threshold.
|
STITCH will halt operation, low voltage will not be supported.
|
No
|
|
|
An instantaneous hardware Low Voltage (LV) trip has been detected due to an overvoltage condition.
|
LV output voltage exceeds the expected overvoltage threshold.
|
STITCH will halt operation, low voltage will not be supported.
|
No
|