Signal Name Description Condition Impact
Not Available
setcondition
These are the repercussions of the alert being set
Not Available
setcondition
These are the repercussions of the alert being set
The SBC CAN transceiver has faulted. Alert will be seen if the trasnceiver has recovered from the faulted condition.
The BDY CAN bus communication is not available.
Other ECUs may report this ECU as being MIA and behaviour will be impacted. This alert won't be seen until CAN communcation has returned.
Check if DOOR_READ_EN is enabled (pulled low) at startup; check that the doorID pins are being set low in correspondence with the desired side; run UDS routine 204 on the bootloader to read and store the side config
The ECU did not read the door ID pins properly on reset
The ECU may not respond to the desired signals
The most common cause of this fault is the MISO line being held low on HSD U19
The Freescale HSD has been returned bad data on the MISO line from the microprocessor more than 10 times in a row.
HSD outputs could toggle endlessly causing lights to strobe forever.
After a record upgrade is successful, resetting the ECU should clear the alert.
Record not found, CRC mismatch, Version mismatch, Version upgrade.
Indicate the state of non-volatile data in the ECU.
Verify that front lights are working correctly.
If any fault is reported over LIN this alert shall be set.
Any lighting function on that lamp may be malfunctioning.
Verify that front lights are working correctly.
If any fault is reported over LIN this alert shall be set.
Any lighting function on that lamp may be malfunctioning.
Log contains stack usage for each task.
Stack usage exceeds 80% for any task.
Stack overflow can occur if there is not enough stack space.
Log contains CPU load for each task.
CPU load exceeds 80%.
High CPU load can indicate ineffecient code.
Production vehicle should not have Debug Jumper in place. Remove jumper from ECU.
ECU Debug Jumper is set.
ECU Debug Jumper will disable SBC watchdog, preventing external watchdog reset protection.
Not Available
BDY_RCM_collision did not match BDY_BCCEN_collision
If any crash signal is active, crash behavior is active
Not Available
setcondition
These are the repercussions of the alert being set
The log data contains failure count and up to five init failure codes.
A task init function returns with an error.
If an init routine fails, software may not opperate correctly.
Not Available
Task could not be scheduled because it was already running or pending.
Failure to run tasks on schedule.
Not Available
setcondition
These are the repercussions of the alert being set
Not Available
setcondition
These are the repercussions of the alert being set
Not Available
setcondition
These are the repercussions of the alert being set
Not Available
Reasons to keep the controller awake have been the same for greater than one hour
The bus could not sleep causing significant range loss for the battery pack
Not Available
A signal is received 10% out of timing 3 times in a row.
These are the repercussions of the alert being set