| Signal Name | Description | Condition | Impact |
|---|---|---|---|
|
Differential Locker (DFLK) Coil Position Sensor is reporting the exact same value repeatedly, indicating the sensor has been disconnected.
|
DFLK Coil Position Sensor is consistently reporting values that are identical.
|
DFLK unable to determine position.
|
|
|
Differential Locker (DFLK) I2C communication with coil position sensor is missing (MIA).
|
Inter-Integrated Circuit (I2C) communication between DFLK and the coil position sensor is lost.
|
DFLK coil unable to determine position.
|
|
|
Drive Inverter unit (DIx) controller area network (CAN) communication to the differential locker (DFLK) is missing (MIA).
|
DFLK is not receiving all expected CAN frames from DIx.
|
DFLK coil unable to communicate to the DIx.
|
|
|
Differential Locker (DFLK) functionality is unavailable. Locker actuation disabled.
|
A condition is present that causes DFLK to be unavailable.
|
DFLK functionality disabled. Locker actuation disabled.
|
|
|
Drive Interface (DI) System controller area network (CAN) communication to the differential locker (DFLK) is missing (MIA).
|
DFLK is not receiving all expected CAN frames from the DI System.
|
DFLK is unable to utilize the unlocked probability signal from DI System and may not be able to auto-calibrate.
|
|
|
Differential Locker (DFLK) coil position sensor has at least one conversion error.
|
Any conversion error bit set in data register.
|
DFLK may not function as expected.
|
|
|
Differential Locker (DFLK) coil position sensor exceeds the maximum number of failures to correctly write to configuration registers.
|
Number of failed write attempts to the configuration registers exceeds the maximum amount.
|
DFLK may not function as expected.
|
|
|
Differential Locker (DFLK) temperature sensor providing a value above threshold.
|
Temperature sensor reads above threshold.
|
DFLK may not function as expected.
|
|
|
Differential Locker (DFLK) input voltage sensor providing a value above upper bound threshold.
|
Input voltage sensor reads above upper bound threshold.
|
DFLK may not function as expected.
|
|
|
Differential Locker (DFLK) input voltage sensor providing a value below lower bound threshold.
|
Input voltage sensor reads below lower bound threshold.
|
DFLK may not function as expected.
|
|
|
DCDC_w012_calibrationFault
|
|
-
|
|
|
A condition affecting Differential Locker (DFLK) non-volatile memory (NVM) is detected by the non-volatile memory manager.
|
Non-volatile memory misconfiguration or underlying flash/filesystem error.
|
Non-volatile memory records may be incorrect or missing.
|
|
|
A condition affecting a particular Differential Locker (DFLK) non-volatile memory (NVM) record is detected by the non-volatile memory manager.
|
Non-volatile memory record not found, CRC mismatch, version mismatch, version upgrade.
|
The particular non-volatile memory record may be incorrect or missing.
|
|
|
Differential Locker (DFLK) measured coil current exceeds overcurrent limit.
|
DFLK measured coil current exceeds expected current limit
|
DFLK unable to properly control coil current
|
|
|
At least one message the Differential Locker (DFLK) expects to receive from the Drive Inverter (DI) is not received.
|
At least one message from the DI consumed by the DFLK is not received.
|
DFLK may lose ability to control the coil
|
|
|
Differential Locker (DFLK) power on self test failed.
|
Coil resistance calculated during self test is out of nominal bounds
|
DFLK may lose ability to control the coil
|
|
|
Differential Locker (DFLK) measured coil current exceeds overcurrent limit.
|
DFLK measured coil current exceeds expected current limit
|
DFLK unable to properly control coil current
|
|
|
A condition affecting a particular Differential Locker (DFLK) non-volatile memory (NVM) record is detected by the non-volatile memory manager.
|
Non-volatile memory record not found, CRC mismatch, version mismatch, version upgrade.
|
The particular non-volatile memory record may be incorrect or missing.
|
|
|
A condition affecting Differential Locker (DFLK) non-volatile memory (NVM) is detected by the non-volatile memory manager.
|
Non-volatile memory misconfiguration or underlying flash/filesystem error.
|
Non-volatile memory records may be incorrect or missing.
|
|
|
Differential Locker (DFLK) input voltage sensor providing a value below lower bound threshold.
|
Input voltage sensor reads below lower bound threshold.
|
DFLK may not function as expected.
|