Signal Name Description Condition Impact Important
iBooster (IBST) has detected the flashed software does not match to the device.
IBST detects flashed software does not match to the device.
IBST may not operate as expected.
No
iBooster (IBST) detected the initial test/check for Application-Specific Integrated Circuit (ASIC) supply parts has failed.
IBST detects intial test/check for ASIC supply parts has failed.
IBST may not operate as expected.
No
iBooster (IBST) monitoring of voltage pre-charge (VPRE) U5V over and undervoltage bits has detected an out of range value.
IBST monitoring of VPRE U5V over and undervoltage bits detects an out of range value.
IBST may not operate as expected.
No
iBooster (IBST) detected the Application-Specific Integrated Circuit (ASIC) current reference is out of range.
IBST detects the ASIC current reference is out of range.
IBST may not operate as expected.
No
Circuit 2 has defect.
Decreased brake capability
No
Low pressure warning for circuit 2.
May not be able to unpark and reduced service brake capability
No
Comparator circuit error detected.
Intervention by comparator may not be possible during low pressure situation
No
Cartridge maintenance prediction alert - worn cartridge.
-
No
Cartridge maintenance prediction alert - overworn cartridge.
Possible moisture in air system
No
Circuit 2 reached max pressure level.
No electronic governing or regeneration available, diagnostic available
No
CAN Bus off failure occurred.
Decreased regeneration efficiency
No
Shunt bar temperature is too low
Shunt bar temperature is too low
This alert is primarily informational and is used for logging purposes. No expected impact on vehicle functionality.
No
Shunt detects shunt connector as disconnected
Shunt active current reads 0A, passive current reflects open circuit conditions
Battery pack may not come online
No
Shunt active sense and passive sense readings are not in agreement
Shunt active sense and passive sense readings have a delta outside of the acceptable margin
Vehicle may not drive or charge.
No
Shunt active sense current reading deviates from zero when contactors are open
Contactors are open and shunt active sense reading is larger than acceptable margin
This alert is primarily informational and is used for logging purposes. No expected impact on vehicle functionality.
No
Energy reserve voltage supply is below minimum voltage threshold
Energy reserve voltage supply is below minimum voltage threshold
pyro diagnostics may fail, the contactors will not close
No
A brick voltage is above the fault voltage limit
A brick voltage is above the fault voltage limit for X duration (in seconds)
The vehicle may not drive or charge.
No
The Bandolier Thermal Model for the battery pack was reset to thermistor temperatures
The absolute delta between the modeled thermistor temperature and the actual is greater than than the reset threshold OR the model inputs become valid
Modeled thermal gradient across pack will be reset to thermistor temperatures
No
A Battery Monitoring Board (BMB) device status register error indication has been detected
Any BMB device in the daisy chain reports any of the monitored error indicators
May indicate a BMB device hardware issue which could result in unreliable measurement data
No
The shunt measurement ASIC is not producing data
Timeout on expected communication
Shunt readings are stale
No