Alerts
Loading...
| Signal Name | Description | Condition | Impact |
|---|---|---|---|
|
Driver Front airbag 2nd stage - Cross Coupled
|
There is a cross coupling with the second stage of the driver airbag.
|
The Driver Airbag may not perform as designed.
|
|
|
Driver Front airbag 2nd stage - Short Circuit
|
There is an issue with the second stage of the driver airbag.
|
The Driver Airbag may not perform as designed.
|
|
|
Driver Front airbag 2nd stage - Resistance too High
|
There is a high resistance with the second stage of the driver airbag.
|
The Driver Airbag may not perform as designed.
|
|
|
Driver Front airbag 2nd stage - Short to Battery
|
There is a short to battery with the second stage of the driver airbag.
|
The Driver Airbag may not perform as designed.
|
|
|
Driver Front airbag 1st stage - Short Circuit
|
There is an issue with the first stage of the driver airbag.
|
The Driver Airbag may not perform as designed.
|
|
|
Pedestrian Collision Event Detected
|
The vehicle impacted an object which resulted in the deployment of the pedestrian protection system.
|
The Pedestrian Safety System may not perform as designed.
|
|
|
RCM2_a004_crashAlgoWakeup
|
The safety system has observed an impact.
|
No Impact.
|
|
|
Driver Front airbag 1st stage - Cross Coupled
|
There is a cross coupling with the first stage of the driver airbag.
|
The Driver Airbag may not perform as designed.
|
|
|
Driver Front airbag 1st stage - Resistance too High
|
There is a high resistance with the first stage of the driver airbag.
|
The Driver Airbag may not perform as designed.
|
|
|
Driver Front airbag 1st stage - Short to Battery
|
There is a short to battery with the first stage of the driver airbag.
|
The Driver Airbag may not perform as designed.
|
|
|
Driver Front airbag 1st stage - Short to Ground
|
There is an issue with the first stage of the driver airbag.
|
The Driver Airbag may not perform as designed.
|
|
|
Power supply voltage is too low
|
The RCM power supply voltage is too low.
|
The Safety Restraint System may not perform as designed.
|
|
|
Power supply voltage is too high
|
The RCM power supply voltage is too high.
|
The Safety Restraint System may not perform as designed.
|
|
|
RCM2_a017_ecuLogAvailable
|
|
-
|
|
|
RCM2_a016_noDeployPedProCal
|
No Deployment PedPro Calibration Present.
|
The Pedestrian Safety System may not perform as designed.
|
|
|
RCM2_a015_noDeployCrashCal
|
No Deployment Crash Calibration Present.
|
The Safety Restraint System may not perform as designed.
|
|
|
RCM2_a014_pedProNearDeploy
|
The vehicle impacted an object which did not result in the deployment of the pedestrian protection system.
|
The Pedestrian Safety System may not perform as designed.
|
|
|
Battery ESR High
|
A problem with the restraint control module energy reserve is detected.
|
The Safety Restraint System may not perform as designed.
|
|
|
PedPro EDR Data Locked
|
The Pedestrian Protection Event Data Recorder has been permanently locked.
|
Additional Event Data may not be stored.
|
|
|
EDR data locked
|
The Event Data Recorder has been permanently locked.
|
Additional Event Data may not be stored.
|