Alerts
Loading...
Signal Name | Description | Condition | Impact |
---|---|---|---|
The pressurized air suspension valve block inlet line routine (PROC_TAS_X_INLET-PRESSURE-CHECK) is unable to confirm the inlet line can hold pressure.
|
The PROC_TAS_X_INLET-PRESSURE-CHECK routine is unsuccessful due to a condition affecting the functionality of the airlines, pressure sensor, and/or valves. Alert log signal data should provide more information on the specific condition(s) detected.
|
Air Suspension raising may be unavailable or may not function as expected.
|
|
The Tesla Air Suspension (TAS) electronic control unit (ECU) has detected pressure above operating limit.
|
The TAS ECU has detected pressure above operating limit.
|
Air suspension leveling may not operate as expected.
|
|
The damper hydraulic type configuration value reported by the vehicle gateway (GTW) does not match the damper hydraulic type supported by the firmware version running on the Tesla Air Suspension (TAS) electronic control unit (ECU).
|
The TAS ECU detects a mismatch between the damper hydraulic type supported by its firmware and the damper hydrualic type reported by the GTW.
|
Adaptive damping controls are unavailable. All dampers receive a fixed current instead for degraded and compromised performance.
|
|
The thermal controller (THC) detects reduced performance in the battery heater.
|
Reduced battery heater performance detected.
|
Battery heater may not operate as expected.
|
|
THC_w0105_coolantBottleLowLevel
|
|
-
|
|
The suspension type configuration value reported by the vehicle gateway (GTW) does not match the suspension type type supported by the firmware version running on the Tesla Air Suspension (TAS) electronic control unit (ECU).
|
The TAS ECU detects a mismatch between the suspension type supported by its firmware and the suspension type reported by the GTW.
|
No expected impact on vehicle functionality.
|
|
THC_w0095_sanityTempBatHeater
|
|
-
|
|
The thermal controller (THC) detects that the battery heater temperature is not within the expected range.
|
Battery heater temperature is detected as not within the expected range.
|
The battery heater will be unable to regulate temperature. Charging may not operate as expected.
|
|
The thermal controller (THC) detects that the battery heater temperature is not within the expected range.
|
Battery heater temperature is detected as not within the expected range.
|
The battery heater will be unable to regulate temperature. Charging may not operate as expected.
|
|
THC_w0029_sanityPumpPT2
|
|
-
|
|
THC_w0028_sanityTempAuxHvacDuct
|
|
-
|
|
THC_w0027_tempAuxHvacDuctRange
|
|
-
|
|
THC_w0026_DASCanTmo
|
|
-
|
|
THC_w0025_pumpPT2Stop
|
|
-
|
|
THC_w0024_pumpPT2Limp
|
|
-
|
|
THC_w0023_tempIncarDriverRange
|
|
-
|
|
THC_w0022_tempIncarDriver
|
|
-
|
|
THC_w0115_sanityBatHeater
|
|
-
|
|
THC_w0021_sanityIncarDriver
|
|
-
|
|
THC_w0020_tempIncarDrvHsgRange
|
|
-
|