Alerts
Loading...
Signal Name | Description | Condition | Impact |
---|---|---|---|
Alert indicating that there has been a communication issue related to the sensor.
|
When the communication error bit is set by the sensor
|
Sensor function will be impaired, park assist features will be disabled.
|
|
UMC vehicle connector exceeded temperature threshold.
|
UMC vehicle connector (charge handle) temperature has risen above 75 C
|
UMC will not allow charging until the charge handle cools sufficiently
|
|
UMC input terminals (UMC side of smart adapter connection) exceeded temperature threshold.
|
UMC input terminal temperature has exceeded 95 C
|
UMC will not allow charging until input terminals cool sufficiently
|
|
UMC wall plug (smart adapter) exceeded temperature threshold.
|
UMC smart adapter temperature exceeded 75 C or the smart adapter specific rating if present
|
UMC will not allow charging until the smart adapter temperature has fallen sufficiently
|
|
UMC proximity line disconnected or vehicle is not providing proximity voltage.
|
Proximity line in charge cable has no voltage present but a vehicle is connected
|
UMC will not allow charging while the proximity line is broken because it cannot determine if the cable is latched
|
|
UMC pilot signal is being pulled to an invalid level or pilot generation circuit failure.
|
Pilot signal transitioned to an invalid voltage level
|
UMC will not allow charging while the pilot signal is invalid
|
|
Timeout while UMC attempted to read smart adapter temperature.
|
UMC was unable to read smart adapter temperature after several retries
|
UMC will only report 8 A charge current capability until the smart adapter temperature can be determined
|
|
UMC GFCI self test failed.
|
GFCI self test failed
|
UMC will not charge until the self test passes. UMC will retest automatically after 15 minutes (except EU smart adapters) or charge cable cycle
|
|
UMC AC input voltage exceeded upper limit.
|
UMC input voltage has risen above 300 V RMS
|
UMC will not allow charging until AC input voltage is within 90-300 V RMS
|
|
UMC ground leakage current exceeded threshold.
|
A ground fault current exceeding detection threshold was detected
|
UMC will not charge until the ground fault is corrected. UMC will retest after 15 minutes (except when an EU smart adapters) or charge cable cycle
|
|
UMC AC input voltage is below lower limit.
|
UMC AC input voltage has fallen below 90 V RMS
|
UMC will not allow charging until AC input voltage is within 90-300 V RMS
|
|
UMC_w010_inputOT
|
|
-
|
|
UMC_w011_proxDisconnected
|
|
-
|
|
UMC detected contactor stuck open or closed.
|
UMC contactor is open when it should be closed (non-EU smart adapter) or closed when it should be open for several seconds
|
UMC will not allow charging if the contactor is stuck in an unexpected state. Charge handle pins may be live and hazardous. Stuck open (non-hazardous) contactors will not trigger this fault with EU smart adapters.
|
|
UMC AC input side ground impedance exceeded threshold.
|
UMC AC input side ground impedance is above 1 Mohm
|
UMC will not allow charging until the protective earth connection is corrected
|
|
UMC_w012_pilotFault
|
|
-
|
|
UMC read smart adapter genealogy data and CRC check failed.
|
UMC smart adapter genealogy was read but the data failed an integrity check
|
UMC will only report 8 A charge current capability until smart adapter genealogy can be read and passes an integrity check
|
|
Infotainment GPU operation timed out.
|
GPU driver reports a fence timeout
|
Touchscreen or UI may not be responsive
|
|
UMC PCB temperature exceeded threshold.
|
UMC PCB temperature exceeded 100 C
|
UMC will not allow charging until the PCB cools off sufficiently
|
|
The User Interface (UI) detects the command to go to sleep was cancelled.
|
The Gateway (GTW) sets the signal GTW_ethGoToSleep=0 after the UI has began preparing for or entering sleep. Alert log signal data should provide more information on the specific condition(s) detected.
|
The UI may appear to be unresponsive while aborting the sleep attempt.
|