Alerts

Alerts

Signal Name Description Condition Impact
The Drive Inverter (DIx) Electronic Control Unit (ECU) has detected an error with Active Driveline Damping (ADD).
The DIx ECU has detected an error with ADD.
Gear train and drive line thuds and noise typically dampened by ADD may be more noticeable.
The Drive Inverter (DIx) power stage has applied a safe state.
The DIx power stage has applied a safe state.
Some DIx features may be disabled, or may not function expected. The Drive Unit may not function as expected.
The drive interface (DI) or drive inverter (DIx) electronic control unit (ECU) detects a condition that leads to the pedal monitor (PM) disabling powertrain.
The PM detects a condition that requires it to intervene and disable powertrain.
Vehicle drive torque is immediately disabled.
The drive interface (DI) or drive inverter (DIx) electronic control unit (ECU) detects a low voltage (LV) battery undervoltage event.
LV supply voltage to DI is disconnected or drops below lower voltage threshold.
The DI ECU triggers limp mode (see separate limpMode alerts) and cannot produce torque or power.
Drive Inverter Warning: Battery over voltage detected in hardware.
HV bus voltage exceeds set upper voltage threshold
Unable to produce torque/power from drive unit
The drive interface (DI) or drive inverter (DIx) electronic control unit (ECU) detects a 5V supply is under voltage.
The FPGA detects a 5V supply regulator PGOOD is not working as expected.
Readings from 5V sensors may become erratic.
The Switch Off Path Test (SOPT) for Drive Unit has failed. The pathway between Drive Inverter (DIx) and Pedal Monitor (PM) torque measurements are different.
The Switch Off Path Test (SOPT) for Drive Unit has failed. The DIx and PM torque measurements are different. The pathway between DIx and PM may have a condition affecting functionality.
PM may not be able to shut down torque produced by Drive Unit.
The Drive Inverter (DIx) Electronic Control Unit (ECU) has detected an overcurrent event (or peak) in Phase A.
The DIx ECU has detected a peak in Phase A.
DIx may be inoperable.
The Drive Inverter (DIx) Electronic Control Unit (ECU) has detected an overcurrent event (or peak) in Phase B.
The DIx ECU has detected a peak in Phase B.
DIx may be inoperable.
The Drive Inverter (DIx) Electronic Control Unit (ECU) has detected an overcurrent event (or peak) in Phase C.
The DIx ECU has detected a peak in Phase C.
DIx may be inoperable.
The Drive Inverter (DIx) Electronic Control Unit (ECU) has detected the current sensor Root Mean Squared (RMS) current has exceeded the expected RMS threshold on Phase A.
The DIx ECU has detected the current sensor RMS current has exceeded the expected RMS threshold on Phase A.
DIx may not function as expected, including vehicle power being limited.
The Drive Inverter (DIx) Electronic Control Unit (ECU) has detected the current sensor Root Mean Squared (RMS) current has exceeded the expected RMS threshold on Phase B.
The DIx ECU has detected the current sensor RMS current has exceeded the expected RMS threshold on Phase B.
DIx may not function as expected, including vehicle power being limited.
The Drive Inverter (DIx) Electronic Control Unit (ECU) has detected the current sensor Root Mean Squared (RMS) current has exceeded the expected RMS threshold on Phase C.
The DIx ECU has detected the current sensor RMS current has exceeded the expected RMS threshold on Phase C.
DIx may not function as expected, including vehicle power being limited.
The Drive Inverter (DIx) Electronic Control Unit (ECU) has detected the current sensor offset has exceeded the threshold on Phase A.
The DIx ECU has detected the current sensor offset has exceeded the threshold on Phase A. Phase A hardware may need investigation.
This alert is intended for logging purposes. Phase A hardware may need investigation.
The Drive Inverter (DIx) Electronic Control Unit (ECU) has detected the current sensor offset has exceeded the threshold on Phase B.
The DIx ECU has detected the current sensor offset has exceeded the threshold on Phase B. Phase B hardware may need investigation.
This alert is intended for logging purposes. Phase B hardware may need investigation.
The Drive Inverter (DIx) Phase A current sensor is irrational.
The DIx Phase A current sensor is irrational. An irrational current may indicate a high rate of change or current measurement out of sensing bounds. There may be a condition affecting current input and output.
If the alert asserts at the beginning of a drive cycle, DIx may not enable. If the alert asserts during a drive cycle, DIx may be disabled. DIx may not function as expected.
The Drive Inverter (DIx) Phase B current sensor is irrational.
The DIx Phase B current sensor is irrational. An irrational current may indicate a high rate of change or current measurement out of sensing bounds. There may be a condition affecting current input and output.
If the alert asserts at the beginning of a drive cycle, DIx may not enable. If the alert asserts during a drive cycle, DIx may be disabled. DIx may not function as expected.
Drive Inverter Warning: Phase current imbalance.
Imbalanced phase currents detected. See payload signals for reason of trigger
Drive unit enters unit limp mode (see DI_a126_limpMode)
Drive Inverter Warning: Battery over voltage detected in software.
HV bus voltage (refer to busVoltage) exceeds upper voltage theshold (refer to busHighLimit)
Unable to produce torque/power from drive unit
Drive Inverter Warning: Battery under voltage.
HV bus voltage (refer to busVoltage) drops below lower voltage threshold (refer to busHighLimit)
Unable to produce torque/power from drive unit