Alerts
Loading...
Signal Name | Description | Condition | Impact |
---|---|---|---|
The Drive Inverter (DIx) Electronic Control Unit (ECU) has detected an error with Active Driveline Damping (ADD).
|
The DIx ECU has detected an error with ADD.
|
Gear train and drive line thuds and noise typically dampened by ADD may be more noticeable.
|
|
The Drive Inverter (DIx) power stage has applied a safe state.
|
The DIx power stage has applied a safe state.
|
Some DIx features may be disabled, or may not function expected. The Drive Unit may not function as expected.
|
|
The drive interface (DI) or drive inverter (DIx) electronic control unit (ECU) detects a condition that leads to the pedal monitor (PM) disabling powertrain.
|
The PM detects a condition that requires it to intervene and disable powertrain.
|
Vehicle drive torque is immediately disabled.
|
|
The drive interface (DI) or drive inverter (DIx) electronic control unit (ECU) detects a low voltage (LV) battery undervoltage event.
|
LV supply voltage to DI is disconnected or drops below lower voltage threshold.
|
The DI ECU triggers limp mode (see separate limpMode alerts) and cannot produce torque or power.
|
|
Drive Inverter Warning: Battery over voltage detected in hardware.
|
HV bus voltage exceeds set upper voltage threshold
|
Unable to produce torque/power from drive unit
|
|
The drive interface (DI) or drive inverter (DIx) electronic control unit (ECU) detects a 5V supply is under voltage.
|
The FPGA detects a 5V supply regulator PGOOD is not working as expected.
|
Readings from 5V sensors may become erratic.
|
|
The Switch Off Path Test (SOPT) for Drive Unit has failed. The pathway between Drive Inverter (DIx) and Pedal Monitor (PM) torque measurements are different.
|
The Switch Off Path Test (SOPT) for Drive Unit has failed. The DIx and PM torque measurements are different. The pathway between DIx and PM may have a condition affecting functionality.
|
PM may not be able to shut down torque produced by Drive Unit.
|
|
The Drive Inverter (DIx) Electronic Control Unit (ECU) has detected an overcurrent event (or peak) in Phase A.
|
The DIx ECU has detected a peak in Phase A.
|
DIx may be inoperable.
|
|
The Drive Inverter (DIx) Electronic Control Unit (ECU) has detected an overcurrent event (or peak) in Phase B.
|
The DIx ECU has detected a peak in Phase B.
|
DIx may be inoperable.
|
|
The Drive Inverter (DIx) Electronic Control Unit (ECU) has detected an overcurrent event (or peak) in Phase C.
|
The DIx ECU has detected a peak in Phase C.
|
DIx may be inoperable.
|
|
The Drive Inverter (DIx) Electronic Control Unit (ECU) has detected the current sensor Root Mean Squared (RMS) current has exceeded the expected RMS threshold on Phase A.
|
The DIx ECU has detected the current sensor RMS current has exceeded the expected RMS threshold on Phase A.
|
DIx may not function as expected, including vehicle power being limited.
|
|
The Drive Inverter (DIx) Electronic Control Unit (ECU) has detected the current sensor Root Mean Squared (RMS) current has exceeded the expected RMS threshold on Phase B.
|
The DIx ECU has detected the current sensor RMS current has exceeded the expected RMS threshold on Phase B.
|
DIx may not function as expected, including vehicle power being limited.
|
|
The Drive Inverter (DIx) Electronic Control Unit (ECU) has detected the current sensor Root Mean Squared (RMS) current has exceeded the expected RMS threshold on Phase C.
|
The DIx ECU has detected the current sensor RMS current has exceeded the expected RMS threshold on Phase C.
|
DIx may not function as expected, including vehicle power being limited.
|
|
The Drive Inverter (DIx) Electronic Control Unit (ECU) has detected the current sensor offset has exceeded the threshold on Phase A.
|
The DIx ECU has detected the current sensor offset has exceeded the threshold on Phase A. Phase A hardware may need investigation.
|
This alert is intended for logging purposes. Phase A hardware may need investigation.
|
|
The Drive Inverter (DIx) Electronic Control Unit (ECU) has detected the current sensor offset has exceeded the threshold on Phase B.
|
The DIx ECU has detected the current sensor offset has exceeded the threshold on Phase B. Phase B hardware may need investigation.
|
This alert is intended for logging purposes. Phase B hardware may need investigation.
|
|
The Drive Inverter (DIx) Phase A current sensor is irrational.
|
The DIx Phase A current sensor is irrational. An irrational current may indicate a high rate of change or current measurement out of sensing bounds. There may be a condition affecting current input and output.
|
If the alert asserts at the beginning of a drive cycle, DIx may not enable. If the alert asserts during a drive cycle, DIx may be disabled. DIx may not function as expected.
|
|
The Drive Inverter (DIx) Phase B current sensor is irrational.
|
The DIx Phase B current sensor is irrational. An irrational current may indicate a high rate of change or current measurement out of sensing bounds. There may be a condition affecting current input and output.
|
If the alert asserts at the beginning of a drive cycle, DIx may not enable. If the alert asserts during a drive cycle, DIx may be disabled. DIx may not function as expected.
|
|
Drive Inverter Warning: Phase current imbalance.
|
Imbalanced phase currents detected. See payload signals for reason of trigger
|
Drive unit enters unit limp mode (see DI_a126_limpMode)
|
|
Drive Inverter Warning: Battery over voltage detected in software.
|
HV bus voltage (refer to busVoltage) exceeds upper voltage theshold (refer to busHighLimit)
|
Unable to produce torque/power from drive unit
|
|
Drive Inverter Warning: Battery under voltage.
|
HV bus voltage (refer to busVoltage) drops below lower voltage threshold (refer to busHighLimit)
|
Unable to produce torque/power from drive unit
|