| Signal Name | Description | Condition | Impact |
|---|---|---|---|
|
Secondary disconnect controller (SDC) bus bar temperature sensors providing irrational values.
|
At least one SDC bus bar temperature sensor value is outside expected range.
|
At least one bus bar temperature is unavailable, which may affect pyro disconnect functionality.
|
|
|
At least one message the Secondary Disconnect Controller (SDC) expects to receive from the vehicle gateway (GTW) is not received.
|
At least one message from the GTW consumed by the SDC is not received.
|
Timestamp for any ECULOG capturing internal SDC data will be inaccurate, which may complicate diagnosis.
|
|
|
SCS_f091_voltageRiseDetection
|
|
-
|
|
|
Drive inverter (DI) switching-feedback (fdbk) pin to secondary disconnect controller (SDC) is in an irrational state.
|
DI switching-feedback pin is set but DI running-feedback is cleared.
|
Pyro disconnect may not function as expected.
|
|
|
Secondary disconnect controller (SDC) reference voltage (Vref) for current sensor measurement is irrational, making SDC unable to monitor drive unit electrical state.
|
SDC reference voltage (Vref) measurement is outside of expected range.
|
Pyro disconnect may not function as expected.
|
|
|
Turn indicator stalk angular speed is outside of the expected operating range.
|
Turn indicator stalk angular speed is greater than 1 degree per millisecond.
|
Turn indicator stalk may not operate as expected.
|
|
|
SCS_f078_voltageMatchTimeout
|
|
-
|
|
|
One or more startup tests has reported an issue. Steering may not operate as expected.
|
One or more of the following startup tests does not pass: Built-In Self-Test (BIST), Secure Boot (sBoot), startup Secure Check (sCheck).
|
Steering functionality may not operate as expected.
|
|
|
Alert for detecting if the chip junction temperature has exceeded 100 C
|
SCCM detected chip junction temperature over 100 C
|
Steering functionality may not operate as expected.
|
|
|
Alert for detecting if the chip junction temperature has exceeded 100 C
|
SCCM detected chip junction temperature over 100 C
|
Steering functionality may not operate as expected.
|
|
|
Alert for detecting if Analog-Digital Converter periodical self-test has failed
|
Analog-Digital Converter periodical self-test has failed
|
Steering functionality may not operate as expected.
|
|
|
Steering Column Control Module (SCCM) detected a gear stalk open circuit.
|
SCCM detected a gear stalk open circuit.
|
Gear stalk may not operate as expected. Gear stalk may not respond to inputs from the user.
|
|
|
One or more runtime tests has reported an issue. Steering may not operate as expected.
|
One or more of the following runtime tests does not pass: runtime Secure Check (sCheck) test or array integrity check.
|
Steering functionality may not operate as expected.
|
|
|
Steering Column Control Module (SCCM) detected a gear stalk short circuit.
|
SCCM detected a gear stalk short circuit.
|
Gear stalk may not operate as expected. Gear stalk may not respond to inputs from the user.
|
|
|
Steering Column Control Module (SCCM) detected a gear stalk generic error.
|
SCCM detected a gear stalk generic error.
|
Alert is primarily informational and used for logging purposes.
|
|
|
Steering Column Control Module (SCCM) detected a steering stalk module run time error.
|
SCCM detected a steering stalk module run time error.
|
Alert is primarily informational and used for logging purposes.
|
|
|
The primary motor position sensor has been deemed invalid.
|
The motor position sensor signals have failed a safety check.
|
The motor is disqualified and rack control health is degraded.
|
|
|
Steering Column Control Module (SCCM) detected a high beam stalk short to ground.
|
SCCM detected a high beam stalk short to ground.
|
High beam control from gear stalk control may not operate as expected.
|
|
|
Steering current calibration is unsuccessful.
|
Motor phase or bus current calibration offset is out of the nominal range.
|
The motor is disqualified and system health is degraded.
|
|
|
The gate driver reported an electrical condition preventing operation.
|
The gate driver is reporting an electrical condition affecting its functionality.
|
The motor is disqualified and system health is degraded.
|