Signal Name Description Condition Impact
The handwheel has not been calibrated
Uncalibrated handwheel detected
Steering control from this node is disabled
The median check fault counter has started to count up
The median check fault counter has started to count up
Loss of redundancy in steering feedback
The Steering Column Control Module (SCCM) steering angle has not been calibrated
Uncalibrated SCCM steering angle detected
Steering performance may be degraded
A stage 1 instantaneous hardware trip has been detected due to a Stage A tank current condition.
The absolute tank current has exceeded the expected threshold.
The condition can lead to potential hardware damage if persistently observed.
An instantaneous hardware Low Voltage (LV) trip has been detected due to an overvoltage condition.
LV output voltage exceeds the expected overvoltage threshold.
STITCH will halt operation, low voltage will not be supported.
An instantaneous hardware Low Voltage (LV) trip has been detected due to an overvoltage condition.
LV output voltage exceeds the expected overcurrent threshold.
STITCH will halt operation, low voltage will not be supported.
A software trip has been detected due to High Voltage (HV) readings exceeding the expected voltage limit.
HV voltage exceeds the expected threshold.
STITCH will halt operation, low voltage will not be supported.
A software trip has been detected due to High Voltage (HV) readings dropping below the expected undervoltage limit.
HV voltage drops below the expected undervoltage threshold.
STITCH will halt operation, low voltage will not be supported.
A fast firmware trip has been detected due to High Voltage (HV) readings exceeding the expected bus top half voltage limit.
Single HV top half bus voltage exceeds the expected threshold.
STITCH will halt operation, low voltage will not be supported.
A software trip has been detected due to the stage 1 Low Voltage (LV) side board temperature sensor exceeding the expected temperature limit.
Stage 1 LV temperature sensor reads above the expected threshold.
STITCH will halt operation, low voltage will not be supported.
A software trip has been detected due to the stage 2 low voltage side board temperature sensor exceeding the expected temperature limit.
Stage 2 LV temperature sensor reads above the expected threshold.
STITCH will halt operation, low voltage will not be supported.
A software trip has been detected due to the stage 1 high voltage side board temperature sensor exceeding the expected temperature limit.
Stage 1 HV temperature sensor reads above the expected threshold.
STITCH will halt operation, low voltage will not be supported.
A software trip has been detected due to the stage 2 high voltage side board temperature sensor exceeding the expected temperature limit.
Stage 2 HV temperature sensor reads above the expected threshold.
STITCH will halt operation, low voltage will not be supported.
The Sigma Delta Filter Module (SDFM) peripheral is not powered, potentially due to not enough DC voltage being provided to the SDFM.
One of the SDFM modules indicates either a clock failure or an irrational reading.
STITCH will halt operation, low voltage will not be supported.
The hardware comparator for measurement tank zero-current crossing has experienced a potential failure.
Tank zero-current cross is invalid for 1 second.
STITCH will halt operation, low voltage will not be supported.
A slow software trip has been detected due to Low Voltage (LV) readings exceeding the expected limit during operation.
LV voltage exceeds the expected threshold for the given time interval.
High rated low voltage causes thermal issues for loads rated at lower voltages.
A software trip has been detected due to High Voltage (HV) bus top half voltage readings exceeding the expected limit during operation.
Single HV top half bus voltage exceeds the expected threshold.
STITCH will halt operation, high voltage will not be supported.
A software trip has been detected due to High Voltage (HV) bus bottom half voltage readings exceeding the expected limit during operation.
Single HV bottom half bus voltage exceeds the expected threshold.
STITCH will halt operation, high voltage will not be supported.
STITCH command Controller Area Network (CAN) messages are not received .
STITCH command CAN messages are Missing In Action (MIA).
STITCH will halt operation, low voltage will not be supported.
An operation on the Electrically Erasable Programmable Read-Only Memory (EEPROM) has failed. This alert provides record ID, error type, and number of errors since the last task loop.
An operation on the EEPROM failed.
The payload signals for this alert will indicate the nature of the error.