VCSUPER_a196_ptPumpStopped
Description
The vehicle controller detects the powertrain pump motor is experiencing a condition that is preventing the motor from running as expected.
Condition
For at least 10.5 seconds, the powertrain pump motor's RPM feedback is less than 800 RPM, or the powertrain pump motor is intermittently or continually given a non-zero flow request.
Clear Condition
The feedback RPM for the powertrain pump motor is consistently greater than 800 RPM for at least 5.5 seconds.
Potential Impact
Powertrain performance may be limited.
Customer Facing Message 1
Not Available
Customer Facing Message 2
Not Available
Audiences
service-fix
Models
Cybertruck