Description
Unexpected voltage seen on non-continuous device outputs. Right mirror fold and tilt, right windows, and HVAC actuators may be disabled
Condition
Voltage is above 8V for 200ms on at least one of the following device outputs while none of them are being driven: right mirror fold and tilt, right windows, and HVAC actuators
Clear Condition
10 seconds after the alert sets. There is a maximum of 3 retries before loads are disabled until an ECU reset
Potential Impact
Right mirror fold and tilt, right windows, and HVAC actuator control may be disabled
Customer Facing Message 1
Not Available
Customer Facing Message 2
Not Available
Audiences
service
Models
Model 3 2017-2023;Model 3 2024+;Model S 2021+;Model X 2021+;Model Y;Model Y 2025+
Important