Alert Details

VCREAR_a206_pcsOvShutdownSelfTestFailure

Description

Power Conversion System (PCS) Overvoltage Shutdown protection has become active on the Rear Vehicle Controller (VCREAR).

Condition

Overvoltage condition on 48V bus detected by VCREAR while the vehicle is in drive.

Clear Condition

PCS Overvoltage Shutdown protection will be reset once the vehicle is parked and the 48V bus voltage is below 56V.

Potential Impact

PCS is unavailable due to overvoltage shutdown protection becoming active. Separate LVUnhealthy alert indicating a condition affecting low voltage (LV) electrical system will also be present.

Customer Facing Message 1

Not Available

Customer Facing Message 2

Not Available

Audiences

service-fix

Models

Cybertruck