VCLEFT_a600_currentSensorMismatch
Description
The current measurement reported by the LV battery (LVBMS_packCurrent) does not match the current sensor on the vehicle controller LV battery feed (IBSCurrent).
Condition
The absolute value of current difference between LVBMS_packCurrent and IBSCurrent exceeds nominal expectations
Clear Condition
The absolute value of current difference between LVBMS_packCurrent and IBSCurrent returns to nominal expectations.
Potential Impact
Incorrect battery current data being used, resulting in sub-optimal LV battery management.
Customer Facing Message 1
Not Available
Customer Facing Message 2
Not Available
Audiences
service
Models
Cybertruck