Alert Details

VCLEFT_a207_exitDriveLowLVBusVoltage

Description

An issue with the low voltage (LV) electrical system requires the vehicle to come to a stop immediately. The vehicle should enter graceful power-off (GPO) to exit drive, and a separate alert should indicate that condition.

Condition

Lead acid: Low voltage (LV) battery voltage below threshold for 3 seconds (3s); transistor gating LV battery connection is open (no current flow); vehicle load shedding is active; or reverse battery transistor issue detected.

Clear Condition

Low voltage (LV) battery voltage above threshold; transistor gating LV battery connection is closed; no reverse battery transistor issue detected; vehicle loadshedding is not active.

Potential Impact

The vehicle will not enter drive. If the vehicle is driving, it will exit drive through graceful power-off (GPO) to come to a stop immediately. A separate alert should be present to indicate the GPO

Customer Facing Message 1

Electrical system power reduced

Customer Facing Message 2

Vehicle shutting down

Audiences

customer;service-fix

Models

Cybertruck