VCLEFT_a142_eFuseManagementContinuous16V
Description
Unexpected voltage seen on continuous device outputs
Condition
Voltage is above 10V for 200ms on at least one of the device outputs while none of them are being driven
Clear Condition
Voltage is below 10V and 10 seconds have passed since alert was set. If the alert sets 3 or more times, controller reset is required.
Potential Impact
Electrical loads for Hydraulic Control Unit (HCU) Electronic Stability Program (ESP) Anti-lock Braking System (ABS) wake line, 1st row seat backrest ventilation fan, 1st row seat cushion ventilation fan, spare (frunk, console, side) High-Side Drivers (HSDs), frunk emergency release switch LED, footwell LED, and B-pillar camera heater may be unavailable.
Customer Facing Message 1
Not Available
Customer Facing Message 2
Not Available
Audiences
service
Models
Cybertruck