Alert Details

VCFRONT_a605_sleepBypassPowerOff

Description

The Front Vehicle Controller (VCFRONT) has detected the sleep bypass voltage is low and cannot support vehicle sleep.

Condition

The sleep bypass voltage is below 8V.

Clear Condition

The sleep bypass voltage is above 8V or VCFRONT is reset.

Potential Impact

The load being precharged may not turn on. Vehicle functions relying on the load being precharged may not operate as expected. The vehicle may not sleep and will experience higher idle range loss

Customer Facing Message 1

Not Available

Customer Facing Message 2

Not Available

Audiences

service-fix

Models

Model 3 2017-2023;Model 3 2024+;Model Y;Model Y 2025+