Alert Details

VCFRONT_a336_pcsFastTripOCMax

Description

The front vehicle controller (VCFRONT) detects the electrical current flowing through the power conversion system (PCS) eFuse has equaled or exceeded 200A during the previous 10 milliseconds.

Condition

The PCS eFuse current value equals or exceeds 200A during the previous 10 milliseconds.

Clear Condition

The PCS eFuse current value remains below 200A during the subsequent 10 milliseconds.

Potential Impact

The eFuse circuit may open (trip), interrupting low voltage power supply to the PCS. This could make PCS functions limited or unavailable, and may interrupt precharging of the high voltage (HV) bus .

Customer Facing Message 1

Not Available

Customer Facing Message 2

Not Available

Audiences

service

Models

Model 3 2017-2023;Model 3 2024+;Model S 2021+;Model X 2021+;Model Y;Model Y 2025+